Design and description
22
01.00 | EGI | Assembly and Operating Manual | en | 1396645
LED
Designation
Color
Function
NS
Network
status
Red /
Green
LED off:
No supply voltage is present and/or no
connection to a PROFINET control.
Lights up green:
Connection to a PROFINET control
present and PROFINET control is in run mode.
LED flashing green once:
Connection to a PROFINET
control present and PROFINET control is in stop mode.
The IRT synchronization is not yet finished.
LED flashing green permanently:
The network participant
is in identification mode.
Lights up red:
severe network fault present.
LED lights up red 1x:
The station name is not known.
LED lights up red 2x:
The IP address is not known.
LED lights up red 3x:
A configuration fault is present.
L/A1 Connection
and commu-
nication of
PROFINET
control
Green
LED off:
Connection inactive, communication inactive
LED lights up green:
Connection active, communication
inactive
LED flickering:
Connection active, communication active
L/A2 Connection
and commu-
nication of
PROFINET
control
Green
LED off:
Connection inactive, communication inactive
LED lights up green:
Connection active, communication
inactive
LED flickering:
Connection active, communication active
PWR Supply power Green
LED off:
No supply voltage power is present.
LED lights up green:
Supply voltage power is present.
LOG Logic supply
Green
LED off:
No logic supply voltage present.
LED lights up green:
Logic supply voltage power is
present.