Copyright © 2020 Axxiom Manufacturing, Inc. 37
6.1.6. Units having electric aftercooler fan motors must be installed by qualified personnel.
Follow manufacturer’s recommendations.
Power connections to AirPrep System with electric motors expose operators to high
electrical voltages. Contact with high electrical voltages can result in serious injury or
death. Only qualified personnel should install or perform maintenance on the electrical
system.
6.1.7. Open drain valves (#3) on the pre-filter (#1) and after-filter (#2), petcock valve (#14) (units
with air motor) and drain valve (#11) on the separator tank to drain out moisture inside.
Note:
These drain valves should be left closed when the unit is not in use.
6.1.8. Close drain valves (#3), (#11) and petcock valve (#14).
6.1.9. Close all the air outlet ball valve(s) (provided by user).
6.1.10. If the unit has an electric aftercooler motor skip to 6.1.13. If the aftercooler has an air
motor, close the air motor on/off ball valve (#13).
6.1.11. Check the reservoir of the air lubricator (#15) for debris in the oil. If necessary, drain the oil
through the petcock valve at the bottom of the bowl. Fill the oil reservoir of the automatic
air lubricator (#15) with detergent SAE #10 automotive engine oil. Lubricator adjustment is
detailed in Sections 5.6 and 7.2.
Note:
Filter/regulator and lubricator arrangement may vary
from what is shown in Figure 6.1.
6.1.12. Tighten the bowls on air filter (#14) and air lubricator (#15).
6.1.13. Check the level of the deliquescent/desiccant tablets (#9). Fill if necessary, through the
upper handway opening (#7). (ADS Systems only)
6.1.14. Properly install the handway (#7) on the separator tank (#12). See Section 6.3.
6.1.15. Turn the aftercooler fan (#4) by hand to be sure that no damage has occurred to fan during
shipment or time of non-use. This will eliminate possible motor burnout.
6.1.16.
Connect an air supply hose to the air inlet on the pre-filter (#1) and install safety clips to
protect against accidental disconnections during operation.
Failure to install safety pins on all hose couplings could result in serious injury or death.
See Sections 5.1, 5.14, and 8.8.
6.1.17.
Connect output air supply hose(s) to the outlet connections on the separator tank (#12)
(ACS Systems) or the after-filter (#2) (ADS Systems) and install safety clips (#21) and hose
whip checks (#22) to protect against accidental disconnections during operation. See
Sections 5.1, 5.14, and 8.8.
Failure to install safety pins and whip checks on all hose couplings could result in serious
injury or death. See Sections 5.1, 5.14, and 8.8.
Summary of Contents for ACS 1200
Page 8: ...8 Copyright 2020 Axxiom Manufacturing Inc THIS PAGE IS INTENTIONALLY BLANK ...
Page 54: ...54 Copyright 2020 Axxiom Manufacturing Inc 9 2 a ACS 400 2500 Aftercooler System Air Motor ...
Page 62: ...62 Copyright 2020 Axxiom Manufacturing Inc 9 6 a ADS 400 2500 Air Dryer System Air Motor ...
Page 66: ...66 Copyright 2020 Axxiom Manufacturing Inc 9 8 a ADS 400 2500 Air Dryer System Electric Motor ...
Page 75: ...Copyright 2020 Axxiom Manufacturing Inc 75 NOTES ...