LaQ07 Framed - Mounting Instructions
GB
2
© Schletter GmbH
•
Gewerbegebiet an der B15
•
Alustraße 1
•
83527 Kirchdorf/Haag i. OB
•
Germany
•
Tel.: +49 8072 9191-200
Fax: +49 8072 9191-9200
•
E-mail: [email protected]
•
www.schletter.eu
•
Updated 08/2012
•
Subject to change without notice
Your contact in the UK: Schletter UK Limited, Tel.: +44 1296 461 800, Fax: +44 1296 461 801, E-mail: [email protected]
o
Mount fasteners
t
Select corresponding distance
a
between fasteners for the respective
module. Measurement
a
is derived
from the module width plus 20 mm.
t
Distance between fasteners
b
should
be taken from the structural analysis
for fasteners - schematic diagram is
displayed in Autokalkulator.
t
Further recommendations are
offered in the structural analysis (for
fasteners).
The number of fasteners required is
also dependent upon the properties
of the roof - please verify details with
the manufacturer!
We recommend the use of a fas-
tener with a slotted hole (e.g. Fix2000
standard). Measurement
a
can there-
fore be optimally adjusted.
LAQ07 can be installed if the distanc-
es between module-bearing profiles
can be precisely set - e-g- trapezoidal
sheet metal roofs, seamed roofs and
cross rails.
a
n
Define the area of installation
t
Concentrate the number of fasteners
in edge and corner zones.
t
Further recommendations are o
ff
ered
in the structural analysis.
Calculation formula:
e = min (x / y or 2
.
h)
x
y
e/4
e/4
e/10
e/10
e/10
e/10
e/4
e/4
h
Building
b
Corner zone
Edge zone
Corner zone
Field zone
Edge
zone
Edge
zone
Corner zone
Edge zone
Corner zone