Programming
BASCAP_TOUCHIT_EN
V04 | 10.2018
78
Flavour settings
705) Milk foam consistency
Controls of the air pump.
Setting [0]:
No air is added with this setting. The result is
hot milk.
Setting [1-20]:
Settings with a high value add a large quan-
tity of air to the foam. The milk foam consi-
stency becomes firmer.
Setting [1]:
Maximum fine foam (micro foam). The bub-
bles are nearly invisible.
Setting [20]:
Very coarse foam with large, visible bubbles.
0-20
The standard value is [0].
"Super steam", "Fine
steam" or "Super & fine
steam" is selected in the
"Steam outlet" system
parameter.
Parameters: Steam settings
Display text
Description
Setting range
Notes
Parameters: Flavour settings
Display text
Description
Setting range
Notes
801) Flavour 1 dosing time
Dosing amount for the beverage flavour
selected for flavour 1.
Actuates pump 1 for flavour 1 while the beve-
rage is being dispensed.
0-60 sec
The standard value is
[0 sec.]
The "Flavour mode" sy-
stem parameter is activa-
ted.
802) Flavour 2 dosing time
Dosing amount for the beverage flavour
selected for flavour 2.
Actuates pump 2 for flavour 2 while the beve-
rage is being dispensed.
0-60 sec
The standard value is
[0 sec.]
The "Flavour mode" sy-
stem parameter is activa-
ted.
803) Flavour 3 dosing time
Dosing amount for the beverage flavour
selected for flavour 3.
Actuates pump 3 for flavour 3 while the beve-
rage is being dispensed.
0-60 sec
The standard value is
[0 sec.]
The "Flavour mode" sy-
stem parameter is activa-
ted.
804) Flavour 4 dosing time
Dosing amount for the beverage flavour
selected for flavour 4.
Actuates pump 4 for flavour 4 while the beve-
rage is being dispensed.
0-60 sec
The standard value is
[0 sec.]
The "Flavour mode" sy-
stem parameter is activa-
ted.