496339 Issue 4
31 of 44
AREA 04 NO P
Meaning: Area Not Assigned to Partition. In the example shown, Area 04 has
a zone type programmed, but has not been assigned to a Partition.
All programmed Areas must be Assigned to one Partition.
Action:
Check Menus 32 and 35.
A2 IN P2 NO Z
Meaning: Empty Area Assigned to Partition. In the example shown Area 2
has been assigned to Partition 2, but there are no zones pro-
grammed to Area 2.
Action:
Check Menu 32.
DUALPLY-V-DELAY
Meaning: You have enabled both Dual Ply Entry and Bell Delay, with Bell
Delay always also enabled. This combination is not allowed.
Action:
Check Menus 67 and 53
DUALPLY-V-ABORT
Meaning: You have enabled both Dual Ply Entry and Alarm Abort at the same
time. Only one of these facilities should be enabled.
Action:
Check Menu 67.
LEVEL B IN 2P
Meaning: Level Assigned to Two Partitions. In the example shown Level B
includes an Area that also belongs to more than one Partition.
Action:
Check Menus 35 and 41.
A IN LC ERROR
Meaning: Area Doesn’t Exist. In the example shown, Level C lists an Area
which doesn’t exist.
Action:
Check Menu 41.
LEVELSET O/P 12
Meaning: Levelset Output Will Not Work. In the example shown, output 12 is
a levelset output, but its assignment means that it will never work.
Action:
Check Menu 51.
NO ZONES IN CA
Meaning: No Zones In Common Area. There are no zones assigned to the
Common Area.
Action:
Check Menus 48 or 49.
Z TYPE IN COM A
Meaning: Flex Zone in Common Area. A Flexi-Zone has been assigned to the
Common Area. This is not allowed.
Action:
Check Menu 32.
8136
Configuration Checking Error Messages