Note: When programming IDIS devices with their intended zone numbers, make sure
that only one IDIS device is connected to the Expander at a time. If necessary
disconnect the Sig lead to all other IDIS devices except the one that is being
programmed. During programming the 8136 sets
all
IDIS devices connected to
the Expander to the same ID number. The factory default for all IDIS devices is
Zone 9, as this is the first IDIS zone available on the system.
To program the IDIS modules:
1.
Key-in 21 and press Enter.
For a 941 expander the display shows:
I.D.I.S. EXP. FITTED
040 ZONES FITTED
For a 942 expander the display shows:
I.D.I.S. EXP. FITTED
136 ZONES FITTED
2.
Press Enter.
For a 941 expander the display shows:
ZONES 1-8 = FSL
9-40 = I.D.I.S.
For a 942 expander the display shows:
ZONES 1-8 = FSL
9-136 = I.D.I.S.
Note: If the display does not show the required number of zones, check the expander
board has been fitted correctly, then repeat Menu 21.
3.
Press Enter.
The display shows:
22:IDIS
PROGRAMMING
4.
Press Enter.
The displays shows:
IDIS LOOP NO 1
NO DEVICE FOUND
5.
There are several types of programming lead. For all types plug the 3-
way Molex connector onto the pins marked 'PROG' on the IDIS Ex-
pander card.
6.
EITHER:
For interfaces and LIMs with a 3-pin Prog connector use a 3-way to 3-
way Molex to Molex lead 485206 and connect the other end onto the
pins marked 'PROG' on the device.
Ensure that the BLUE lead is
located on the pin marked with a star (*).
OR: For LIMs with a 2-pin Prog connector use
3-way to 2-way Molex to
Molex lead 485208. Connect the 2-pin Molex end onto the pins marked
'PROG' on the LIM.
Ensure that the BLUE lead is located on the pin
marked with a star (*).
Connect the flying red lead to 12V on the
LIM.