OR: For interfaces or SABs with a 2-pin PROG connector use a 3-way to 2-
way Molex to Molex lead 485208. Connect the 2-pin Molex end onto the
pins marked 'PROG' on the device.
Ensure that the BLUE lead is
located on the pin marked with a star (*).
OR: For IDIS sensors use the 3-way Molex to 2-way Molex lead 485208.
Connect the 2-pin Molex end onto the detector's PROG pins.
Ensure
that the BLUE lead is located on the pin marked with a star (*)
.
Connect the red flying lead to the 12V terminal on the detector's IDIS
connector.
OR: For universal modules use the 3-way Molex to croc clip lead 485207.
Connect the BLUE clip to the purple wire (Sig), black clip to the black
wire (0V), and red clip to the red wire (12V).
7.
Press Enter.
The display shows (for example):
IDIS LOOP NO 1
PROG DEVICE Z009
If the display shows any other message, see "IDIS Programming
Errors".
8.
Use the up and down arrow keys to select the correct loop number. The
system will change the zone number to the appropriate one for the
selected loop. For example:
IDIS Loop 1 contains zones 9 to 40, the display shows Z009
IDIS Loop 2 contains zones 41 to 72, the display shows Z041
IDIS Loop 3 contains zones 73 to 104, the display shows Z073
IDIS Loop 4 contains zones 105 to 136, the display shows Z105
9.
Press Enter.
The display shows (for example):
IDIS LOOP NO 2
PROG DEVICE Z041.
10. Use the up and down arrow keys to select the appropriate zone number.
(You can also key in a number in the range 09 to 40 (OR 136) to select
the zone number directly.) Press Enter to confirm your choice.
The display shows:
IDIS LOOP NO 2
PLEASE WAIT
Followed by confirmation of the module's address,
for example:
IDIS LOOP NO 2
DEVICE IS Z041
8136
Programming for IDIS