74
SCAIME Manual : NU-eNod4B-ETH-E-236708-D.docx
12.2.3
Conveyor
Parameter
Possible Value
Description
Conveyor Parameters
Page 1/2
Conveyor total
Length
Defines the total length of the belt in meters.
Belt Inclination
0.00 – 35.00 deg
Defines the belt title angle in degrees.
Min Weight *
For totalization
0.00 – 655.35
eNod4 enables totalization when “minimum weight to totalize” divided by
“weight section length” is greater than the minimum load to totalize.
Weight Frame *
Length
0 – 65535 mm
Represents the effective belt weigh frame length expressed in millimeters.
The effective weight section length corresponds with half of the distance
between the belt rollers which are found before and after the roller with
the belt scale.
Page 2/2
Auto. Zero
Correction
Yes / No
Dynamic zero auto-correction activation
Conveyor Zero Band
0 - 65535
Defines limit values for dynamic zero correction function. Zero function is
cancelled when the weight is out of these limits.
Material Routine
Time
0 – 6535 sec
Defines time for materials to travel distance from shear gate to weigh
section at normal speed.
Conveyor starting
alarm duration
0 – 3500 sec
For security reason, eNod4 provides buzzer function on logical output at
belt start. The buzzer duration depends on this parameter value in second.
Number of
Revolutions
1 - 65535
Specifies the real belt revolutions to realize during speed/length
calibrations and dynamic zero procedure.