31
SCAIME Manual : NU-eNod4B-ETH-E-236708-D.docx
10
OUTPUTS FUNCTIONING
Each output can work individually in its own logic.
10.1
Outputs assignment:
Outputs individually might be assigned to following functions:
function
Operating mode
transmitter
Belt scale
Belt weigh feeder
none
●
●
●
set point
●
●
●
motion
●
●
●
defective measurement
●
●
●
input image
●
●
●
level on request
●
●
●
belt alarms
●
●
external totalizer
●
●
belt system running
●
●
batch in progress
●
●
batch result available
●
●
conveyor starting alarm
●
●
material TOR gate
●
●
motor activated
●
●
10.2
General functions:
10.2.1
None:
The output has no function
10.2.2
Set point:
The outputs can be assigned to configurable set points (cf. §8) Output 1 is assigned to set point 1, output 2 to set point 2,
output 3 to set point 3 and output 4 to set point 4.
Set points are characterized by a high and a low value.
Their operating mode is either
operating in hysteresis
or
operating in window
.