2.2.4. Specifications
The table below summarizes all mechanical and environmental specifications.
Electrical and Mechanical Specifications
Enclosure materials
Anodized Aluminum (6061)
Dimensions
15 x 16.8 x 21.5 cm
Weight
4290 g
Input power voltage
18 – 32VDC
Power consumption
12W typical
Environmental specifications
Altitude rating
55,000 feet
IP rating
IP-67
Humidity
Sealed, no limit
Operating Temperature
range
-20 to 60°C – specified range
-40 to 71°C – operating range
Storage Temperature range
-40 to 71°C
Shocks
6.0g; 20ms half-sine (operational)
40g; 15 ms half-sine (non operational)
Operating Vibrations
4.1g RMS – DO-160F, Cat. SC
Calibration interval
None required, maintenance free
17/74