background image

Savant IP Audio Deployment Guide 

 

Copyright © 2017 Savant System, LLC 

009-1551-00  |  171121 

3    of    34 

 

 

 

Important Safety Information - Read First 

Before installing, configuring, and operating Savant equipment and other 
vendor equipment, Savant recommends that each dealer, integrator, 
installer, etc. access and read all the required technical documentation.  
Savant technical documentation can be located by visiting 

Savant.com

.  

Vendor documentation is supplied with the equipment. 

Read and understand all safety instructions, cautions, and warnings in 
this document and the labels on the equipment. 

Safety Classifications in this Document 

NOTE: 

Provides special information for installing, 
configuring, and operating the equipment. 

 

 IMPORTANT! 

Provides special information that is critical to 
installing, configuring, and operating the equipment.

 

 CAUTION! 

Provides special information for avoiding situations 
that may cause damage to equipment.

 

 WARNING! 

Provides special information for avoiding situations 

that may cause physical danger to the installer, end 
user, etc.

 

Electric Shock Prevention 

 

ELECTRIC SHOCK!

 

The source power poses an electric shock hazard that has the 
potential to cause serious injury to installers and end users. 

 

ELECTRICAL DISCONNECT:

 

The source power outlet and power supply input power sockets 
should be easily accessible to disconnect power in the event of an 
electrical hazard or malfunction. 

Weight Injury Prevention 

 

WEIGHT INJURY!

 

Installing some of the Savant equipment requires two installers to 
ensure safe handling during installation. Failure to use two installers 
may result in injury. 

 
 
 
 
 

Safety Statements 

Follow all of the safety instructions listed below and apply where 
applicable. Additional safety information will be included where 
applicable. 
1.

 

Read these instructions. 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with dry cloth. 

7.

 

Do not block any ventilation openings.  Install in accordance with 
the manufacturer's instructions. 

8.

 

Do not install near any heat sources such as radiators, heat 
registers, stoves, or other apparatus (including amplifiers) that 
produce heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-
type plug.  A polarized plug has two blades with one wider than the 
other.  A grounding type plug has two blades and a third grounding 
prong.  The wide blade or the third prong is provided for your 
safety.  If the provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched 
particularly at plugs, convenience receptacles, and the point where 
they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Use only with the cart, stand, tripod, bracket, or table specified by 
the manufacturer, or sold with the apparatus. When a cart is used, 
use caution when moving the cart/apparatus combination to avoid 
injury from tip over. 

13.

 

Unplug this apparatus during lightning storms or when unused for 
long periods of time. 

14.

 

Refer all servicing to qualified service personnel.  Servicing is 
required when the apparatus has been damaged in any way, such 
as power supply cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has 
been dropped. 

15.

 

To completely disconnect this equipment from the AC mains, 
disconnect the power supply cord plug from the AC receptacle.

Summary of Contents for SMA-5000 Series

Page 1: ...Guide Copyright 2017 Savant System LLC 009 1551 00 171121 1 of 34 Savant IP Audio SMA 5000 PAV SIPA125 PAV AIM7C PAV AOM8C Deployment Guide Document Number 009 1571 00 Document Date November 2017 Docu...

Page 2: ...on 14 4 8 Checking and Replacing the Fuse 15 5 Installation 16 5 1 SMA 5000 16 5 2 PAV SIPA125 17 5 3 PAV AIM7C PAV AOM8C 17 6 Blueprint Configuration 18 6 1 Basic Blueprint Layout 18 6 2 Adding a Sav...

Page 3: ...nd apply where applicable Additional safety information will be included where applicable 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use...

Page 4: ...through this document in its entirety and ensure that the following required items are available Savant IP Audio device s Unique ID UID of the Savant IP Audio device s located on the back of the devic...

Page 5: ...record which steps have been completed 1 Review product specifications and connection details See Savant IP Audio Equipment Overview 2 Install the Savant IP Audio devices See Savant IP Audio Equipment...

Page 6: ...d firmware Hardware Failure If a hardware failure occurs the status LED indication will be interrupted every three seconds with a solid red indication For example if the LED is blinking green when a h...

Page 7: ...R receiver via an IR flasher 5V tolerant only See IR Wiring section for important precautions regarding IR functionality before making any connections RS 232 2 RS 232 Ports 8 pin RJ 45 port used to tr...

Page 8: ...but no communication has been established with the host Green Host has established communications with the embedded system Red Blinking Embedded firmware is running but has not received a DHCP IP Add...

Page 9: ...R Connectors to send IR signals to control devices with an IR input or IR receiver via an IR flasher 5V tolerant only See IR Wiring section for important precautions regarding IR functionality before...

Page 10: ...tus LED will rapidly blink red when reset is complete RS 232 8 pin RJ 45 port used to transmit and receive serial binary data to and from serial controllable devices CTS RTS handshaking availability b...

Page 11: ...d link local IP Address and is connecting to the host Rear Panel Reset Resets the network settings of the device Hold Reset Button for 5 seconds while powered on to clear network settings Status LED w...

Page 12: ...he exposed wire to be inserted into the terminal up to the insulation eliminating stray strands that may cause shorting RS 232 Pinout RJ 45 to DB9 Serial Control Adapters Refer to the RS 232 Conversio...

Page 13: ...The wire slips into the hole and locks with a screw located at the top of the connector IMPORTANT IR Wiring Precautions Ensure that all IR emitters are within 15 feet 4 6 meters from the controller s...

Page 14: ...hen a device is controlled via a normally open NO or normally closed NC relay 4 6 Network Connection The Savant IP Audio devices use a standard RJ 45 port complying with IEEE 802 3 Ethernet standards...

Page 15: ...ccess to the fuse cartridge 3 Using a flat head screwdriver or similar thin flat head tool gently loosen the cartridge and pull the cartridge out of the unit slowly As the cartridge is removed make no...

Page 16: ...1 SMA 5000 Rack Installation The SMA 5000 can be mounted in a 2U rack style enclosure and is compatible with all standard 19 inch NEMA rack mounts The rack bracket needs to be attached prior to placi...

Page 17: ...mounted in a 2U rack style enclosure and is compatible with all standard 19 inch NEMA rack mounts The rack bracket needs to be attached prior to placing in a rack 5 3 PAV AIM7C PAV AOM8C The PAV AIM7C...

Page 18: ...Savant IP Audio Deployment Guide Copyright 2017 Savant System LLC 009 1551 00 171121 18 of 34 6 Blueprint Configuration 6 1 Basic Blueprint Layout...

Page 19: ...to a Shared Equipment zone HELPFUL INFO It is recommended to place any type of A V switch in a Shared Equipment zone If placed in a User zone the outputs cannot leave that zone 4 Name the Device 5 Pla...

Page 20: ...The Digital Audio Output TOSLINK cannot be assigned this way To assign outputs on the Pro Audio 4 do the following steps 1 Select the Pro Audio 4 device 2 Open Inspector 3 Click the Show drop down 4 S...

Page 21: ...P Address of the IP Audio device is needed To retrieve the IP Address of the switch follow the steps in Appendix C 1 On the SDE open a Web Browser and enter the address of the switch in the address ba...

Page 22: ...t IP Address and allows for entry This is automatically assigned when item A is set to DHCP Subnet Mask Subnet mask of the network This is automatically assigned when item A is set to DHCP Router IP A...

Page 23: ...n the device Output Channels Stereo or Mono Clicking this field will toggle between the Stereo and Mono Mono Summing combines the left and right input signal into a single speaker channel output Proce...

Page 24: ...Up to sixteen Savant IP Audio devices can be connected using a MOTU AVB switch or a compatible switch certified for AVB TSN switching 8 1 Blueprint Layout 5 IP Audio devices This image shows just the...

Page 25: ...4 8 2 Adding an AVB TSN Switch 1 From Blueprint Click Show Library 2 Search for MOTU 3 Drag into a Shared Equipment zone 4 Name the Device 5 Place the MOTU switch in the layout window and make AVB con...

Page 26: ...e of popular music streaming services such as Pandora or Spotify streaming music service fee may apply For a full list of supported services see Savant Media Server Savant Music Supported Streaming Se...

Page 27: ...ill not display Examples Audio from device A that outputs from device B will display Audio from device A and outputting the same device will not display AVB Stations All AVB TSN compliant Savant produ...

Page 28: ...g Displays the Autonomic license serial number Airplay Airplay settings there is a limit of 32 characters for the Airplay name HELPFUL INFO Savant recommends changing the Airplay Name If more than one...

Page 29: ...change due to a power outage a static IP Address or DHCP reservation should be configured Savant recommends using DHCP reservation within the router By using this method static IP Addresses for all de...

Page 30: ...Audio Deployment Guide Copyright 2017 Savant System LLC 009 1551 00 171121 30 of 34 Appendix B Document Revision History 009 1571 00 November 2017 Section Update All Initial releases of this Deployme...

Page 31: ...bSnanner NOTE The UID is needed to verify that the correct IP Address is being checked Record the UID from the sticker located on the rear of the unit Have Savant Application Manager active 1 Active d...

Page 32: ...indow on a MacBook SDE 2 Enter ssh RPM IP Address of IP Audio device Example ssh RPM 10 0 200 45 3 When prompted enter the password Default RPM 4 Once logged in the commands below will add remove or q...

Page 33: ...prior to implementation so that the integrator understands how the system will respond during shutdown and start up periods Power consumption monitoring It is nice to have the ability to monitor the d...

Page 34: ...ant Systems LLC All rights reserved Savant Savant App Savant Host Now You Can RacePoint Blueprint Single App Home TrueCommand TrueControl and the Savant logo are trademarks of Savant Systems LLC AirPl...

Reviews: