Page 4-3
Section 4. Electric Checks and Adjustments
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
4.3 DC Power Voltage Checks
To check voltage levels, first check the fuses (Section 6.3) and replace if necessary. Then
remove the LH cover, (Section 4.2) and perform the following steps.
Addtional equipment required:
TP Test Module
Digital Multimeter
STEP
PROCEDURE
Refer to illustrations on pages 4-3 through 4-5.
1.Attach the connector from the TP Test Module to the test port on
the main PCB. Note correct positioning of connector. Nibs on the
connector are placed down in the receptacle on the PCB in the
forward position.
2.Attach the ground probe of the multimeter to the TP Test Module
Gnd pin.
3.Attach the positive probe of the multimeter to the +SIG pin on
the TP Test Module terminal.
4.Turn printer on and rotate the dial to a dial POS on the TP Test
Module.
Record the values from the Multimeter LCD.
5.Confirm voltages are correct.
If not, then replace power supply.
Refer to Section 6.4.
6.After performing tests, replace the LH cover to the printer.
POWER SUPPLY
TEST POINT
CONNECTOR
MAIN PCB
VR1 OFS
INTERFACE
BOARD
VR4 GAP
VR5 IM
CN13
VR2 DEM
VR3 CE
Summary of Contents for CL608e
Page 1: ...CL608e CL612e Printers Service Manual PN 9001079 Rev B...
Page 6: ...iv SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 106: ...Page 5 14 Section 5 Mechanical Adjustments SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 146: ...Page 6 40 Section 6 Replacement Procedures SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 154: ...Page 7 8 Section 7 Factory Resets SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 172: ...Page 8 18 Section 8 Troubleshooting SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 198: ...Page 9 26 Section 9 Optional Accessories SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 242: ...Page 10 44 Section 10 Parts List SATO CL608e CL612e Service Manual PN 9001079 Rev B...