Page 2-27
Section 2. Configuration
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
EYE
- When setting the "EYE" threshold, the voltage must be measured with nothing but
the label under the sensor and then again with the printed "eye" mark under the sensor.
The formula to be used for this is:
(High Voltage Level + Low Voltage Level) x 0.5 = Start Value
STEP
PROCEDURE
1.
Insert a label into the sensor and close the Label Hold-Down. Make
sure the printed "eye" mark in not under the sensor. Record the
voltage shown on the top line of the LCD panel. This line should have
the message "EYE" on the top line (DIP switch DSW2-2 = ON).
2.
Now pull the label forward until the "eye" mark is positioned under
the sensor (the voltage reading should be at its highest point). Record
the voltage shown on the top line of the LCD panel. The voltage
ranges measured should be within the following ranges:
Label Only = 0.3 - 0.5V
Eye-mark = Equal to or greater than 1.2V
above the low value.
If the measured values are outside this range, you may have trouble
finding a value that will work properly under all conditions. If this is
the case, a higher quality label may be needed to get adequate
performance.
3.
Calculate the starting point voltage using the formula.
4.
Use the
LINE
key to step the counter to the desired setting. The
display will increment one step for each time the
LINE
key is pressed.
If the
LINE
key is held down for more than two seconds, it will
automatically go into the fast scroll mode. The reading will advance
to a setting of 3.3 (the maximum voltage) after which it will
automatically wrap and start at "0.0" again. If a value of "0.0" is set,
the printer will automatically set the level each time the printer is
powered on with labels loaded or the head is closed.
5.
Once the setting is correct, pressing the
FEED
key will accept the
setting and advance to the Auto Online Feed display.
eye
[x.xv]
input
[x.xv]
LCD Panel — Service Mode
Eye
[X.XV]
Input
[X.XV}
Summary of Contents for CL608e
Page 1: ...CL608e CL612e Printers Service Manual PN 9001079 Rev B...
Page 6: ...iv SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 106: ...Page 5 14 Section 5 Mechanical Adjustments SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 146: ...Page 6 40 Section 6 Replacement Procedures SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 154: ...Page 7 8 Section 7 Factory Resets SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 172: ...Page 8 18 Section 8 Troubleshooting SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 198: ...Page 9 26 Section 9 Optional Accessories SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 242: ...Page 10 44 Section 10 Parts List SATO CL608e CL612e Service Manual PN 9001079 Rev B...