Page 6-27
Section 6. Replacement Procedures
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
6.10 Replacing the Ribbon Motion Sensor
STEP
PROCEDURE
1.
Switch the printer
OFF
and disconnect the power cable.
2.
Remove (3) screws holding the left side cover to the printer. Raise the
access door and loosen the (2) screws on the inside top of the printer. Lift
off the left side cover to expose the main PCB. Refer to Section 4-2.
3.
Remove the ribbon and label stock if installed.
Fig. 6-49
4.
Remove the sensor mounting screw
Figs. 6-50 & 6-51
5.
Unplug the SEN4 connector from the PCB harness and pull the sensor cable
and connector through the frame hole.
Figs. 6-52 & 6-53
6.
Remove (2) screws holding the sensor to the bracket.
Figs. 6-54 & 6-55
7.
Replace sensor and reattach to the mounting bracket. Feed new sensor
connector back through the frame hole and reattach SEN4 on the PCB.
Attach the sensor bracket to the frame insuring alignment pin is in
correctly.
Fig. 6-50
8.
Replace the left side cover and reconnect the power cable.
The Ribbon Motion Sensor is easily replaced for service.
Fig. 6-49
REMOVE THE
RIBBON AND
LABEL STOCK
Summary of Contents for CL608e
Page 1: ...CL608e CL612e Printers Service Manual PN 9001079 Rev B...
Page 6: ...iv SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 106: ...Page 5 14 Section 5 Mechanical Adjustments SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 146: ...Page 6 40 Section 6 Replacement Procedures SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 154: ...Page 7 8 Section 7 Factory Resets SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 172: ...Page 8 18 Section 8 Troubleshooting SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 198: ...Page 9 26 Section 9 Optional Accessories SATO CL608e CL612e Service Manual PN 9001079 Rev B...
Page 242: ...Page 10 44 Section 10 Parts List SATO CL608e CL612e Service Manual PN 9001079 Rev B...