background image

SATEL AXD-200 

ATD-200 

Temperature detector 

  Detects exceeding of the predefined temperature threshold. 

  Two programmable temperature thresholds. 

  Occupies 2 positions on the device list (optionally 1 – you can program just one 

temperature threshold). 

  In the ABAX system, the detector is identified as ATD-100. 

AFD-200 

Water flood detector 

  Detects flooding in spaces provided with water installation. 

  Occupies 1 position on the device list. 

  In the ABAX system, the detector is identified as AFD-100. 

The water flood detector requires you to purchase the FPX-1 probe, offered by 
SATEL. 

2  Description 

Radio communication 

The detector connects to the controller / control panel at regular time intervals to provide 
information about its state (periodical communication). Additional communication may take 
place as a result of alarm (see “Operating modes”). 

Alarms 

Described below are circumstances in which the detector reports alarm, depending on the 
detector type. Irrespective of the detector type, tamper alarm is reported on opening the 
tamper contact. 

AMD-200 / AMD-201 

The detector will report alarm: 

  after moving the magnet away from the detector (opening the window or door), 

  after opening the NC type input. 

AMD-202 

The detector will report alarm: 

  after moving the magnet away from the detector (opening the window or door), 

  after opening the NC type input, 

  after registering the specified number of pulses within a defined time period by the roller 

shutter input, 

  after opening the roller shutter input (tamper alarm). 

AVD-200 

The detector will report alarm: 

  after detecting a shock caused by impact, 

  after moving the magnet away from the detector (opening the window or door). 

Summary of Contents for AMD-100

Page 1: ...AXD 200 Wireless multipurpose detector Firmware version 1 00 axd 200_en 03 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Page 3: ...d in the ABAX system as AMD 100 This manual applies to the detector with firmware version 1 00 which is supported by ABAX 2 ACU 220 ACU 280 controller ARU 200 repeater ABAX ACU 120 ACU 270 controller...

Page 4: ...BAX system the detector is identified as AMD 101 AMD 202 Magnetic contact with input for roller shutter detector Detects open door window etc Input for connecting a wired roller shutter detector Input...

Page 5: ...ate periodical communication Additional communication may take place as a result of alarm see Operating modes Alarms Described below are circumstances in which the detector reports alarm depending on...

Page 6: ...ht at which the probe is installed The detector reports end of flooding a few seconds after the water level drops below the height at which the probe is installed Operating modes Active information ab...

Page 7: ...tor inside after opening the enclosure terminal block COM common ground M1 input supported in the case of the AMD 200 AMD 201 AMD 202 and AFD 200 detectors It allows connection of an NC type detector...

Page 8: ...frame for this purpose This will reduce the probability of the detector being flooded accidentally when the window is partially or full open The following tools will be useful to mount the detector b...

Page 9: ...location of installation 7 Open the detector enclosure Fig 3 8 If detectors or flood probe are to be connected to the additional input terminals make a hole in the enclosure base run wires through the...

Page 10: ...8 AXD 200 SATEL...

Page 11: ...d be determined experimentally after securing the detector to the surface ARD 200 after changing the detector position AFD 200 after submerging the flood probe in water 15 For the water flood detector...

Page 12: ...p to 2000 m ACU 280 up to 1200 m ABAX up to 500 m Battery CR123A 3 V Battery life expectancy up to 2 years NC type input sensitivity 240 ms Temperature measurement range 10 C 55 C Temperature measurem...