The detector reports alarm when it senses a change in its position. The detector remembers 
position at the moment of being switched into active mode or starting the test mode. Fig. 1 
shows the changes in orientation that can be sensed by the detector. 

 

ATD-200 

The detector reports alarm when it registers a temperature higher / lower than the predefined 
threshold. The detector allows you to program two critical temperature thresholds: low (L) 
and high (H). The detector will alert of the threshold being exceeded if the temperature: 

  drops below the value preprogrammed for the 

low (L)

 threshold, 

  rises above the value preprogrammed for the 

high (H)

 threshold. 

Information about the current temperature is sent when the detector connects to the 
controller / control panel. 

AFD-200 

The detector reports alarm approximately 5 seconds after the water level reaches the height 
at which the probe is installed. The detector reports end of flooding a few seconds after the 
water level drops below the height at which the probe is installed. 

Operating modes 

Active

 – information about each alarm is sent immediately. 

Passive

 – only information about tamper alarm is sent immediately. This operating mode 

prolongs the battery life. 

The detector operating mode is turned on remotely. If the detector is used in the INTEGRA / 
VERSA alarm system, the operating mode may depend on the partition state (partition 
disarmed – passive mode; partition armed – active mode). For more information, refer to the 
ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL control panel manual. 

Energy saving mode (ECO) 

If you want to prolong the battery life, you can enable in the detector the “ECO” option. When 
the “ECO” option is enabled, the periodical communication takes place every 3 minutes. Thus 
the battery life can be increased as much as fourfold. The option is only available in the 
ABAX 2 system. The detector with “ECO” option enabled meets requirements of the 
EN50131-2-6 standard for Grade 2. 

Summary of Contents for AMD-100

Page 1: ...AXD 200 Wireless multipurpose detector Firmware version 1 00 axd 200_en 03 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Page 3: ...d in the ABAX system as AMD 100 This manual applies to the detector with firmware version 1 00 which is supported by ABAX 2 ACU 220 ACU 280 controller ARU 200 repeater ABAX ACU 120 ACU 270 controller...

Page 4: ...BAX system the detector is identified as AMD 101 AMD 202 Magnetic contact with input for roller shutter detector Detects open door window etc Input for connecting a wired roller shutter detector Input...

Page 5: ...ate periodical communication Additional communication may take place as a result of alarm see Operating modes Alarms Described below are circumstances in which the detector reports alarm depending on...

Page 6: ...ht at which the probe is installed The detector reports end of flooding a few seconds after the water level drops below the height at which the probe is installed Operating modes Active information ab...

Page 7: ...tor inside after opening the enclosure terminal block COM common ground M1 input supported in the case of the AMD 200 AMD 201 AMD 202 and AFD 200 detectors It allows connection of an NC type detector...

Page 8: ...frame for this purpose This will reduce the probability of the detector being flooded accidentally when the window is partially or full open The following tools will be useful to mount the detector b...

Page 9: ...location of installation 7 Open the detector enclosure Fig 3 8 If detectors or flood probe are to be connected to the additional input terminals make a hole in the enclosure base run wires through the...

Page 10: ...8 AXD 200 SATEL...

Page 11: ...d be determined experimentally after securing the detector to the surface ARD 200 after changing the detector position AFD 200 after submerging the flood probe in water 15 For the water flood detector...

Page 12: ...p to 2000 m ACU 280 up to 1200 m ABAX up to 500 m Battery CR123A 3 V Battery life expectancy up to 2 years NC type input sensitivity 240 ms Temperature measurement range 10 C 55 C Temperature measurem...

Reviews: