SATEL AXD-200
5
Test mode
The test mode makes the detector testing easier, because the LED indicator is enabled. How
to start and end the test mode is described in the ABAX 2 / ABAX controller manual / the
INTEGRA 128-WRL control panel manual.
LED
The LED is flashing rapidly for about 10 seconds after the battery is inserted to indicate that
the process of selecting the detector type can be initiated (see “Selecting detector type”).
The LED also works in the test mode, in which it indicates:
periodical communication – short flash (80 milliseconds),
alarm – ON for 2 seconds.
Battery status control
When the battery voltage is below 2.75 V, information about low battery is sent during each
transmission.
Electronics board
Do not remove the electronics board from the enclosure to
avoid damage to the components on the board.
Fig. 2 shows the detector inside after opening the enclosure.
terminal block:
COM
- common
ground.
M1
- input supported in the case of the AMD-200, AMD-201,
AMD-202 and AFD-200 detectors. It allows connection of
an NC type detector (AMD-200 / AMD-201 / AMD-202) or
the flood probe (AFD-200).
M2
- input supported in the case of the AMD-202 detector. It
allows connection of the roller shutter detector.
To make the connection, use wires with a cross-section of 0.5-
0.75 mm
2
. If no detector or flood probe is connected to the input,
the terminal must be connected to common ground.
tamper contact.
CR123A lithium battery.
3 Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.