The detector is designed for indoor installation. Installing the detector in close vicinity of
electrical systems is not recommended, since it can adversely affect the range of radio
signal.
Mount the detector on fixed surface. In the case of magnetic contacts (AMD-200 / AMD-201 /
AMD-202 / AVD-200), mount the detector on the window / door frame (fixed surface), and the
magnet on the window / door (moving surface). Mounting the magnetic contact on
ferromagnetic surfaces and/or near to strong magnetic and electrical fields is not advisable,
because it can result in malfunctioning of the device.
If the detector is to be installed on the window frame, select the upper part of the frame
for this purpose. This will reduce the probability of the detector being flooded
accidentally, when the window is partially or full open.
The following tools will be useful to mount the detector:
blade screwdriver 1.8 mm,
Phillips
screwdriver,
precision
pliers,
drill with a set of drill bits.
1. Open the detector enclosure (Fig. 3). The enclosure opening tool, shown in the
illustration, is included in the detector delivery set.
2. Install the battery and select the detector type (see “Selecting detector type”).
3. Add the detector to the wireless system (see the ABAX 2 / ABAX controller manual or the
INTEGRA 128-WRL control panel installer manual). The sticker with serial number which
shall be entered when registering the detector in the system can be found on the
electronics board.
In the INTEGRA / VERSA alarm system the detector is identified the same as in the
ABAX system (cf. table 1).