![SASFORKS EX-25 v1 Manual Download Page 17](http://html1.mh-extra.com/html/sasforks/ex-25-v1/ex-25-v1_manual_1199898017.webp)
SAS/op/proc/forks/op manuals/Ex/EXTREME MANUAL
v13
.pub 2/24/2019
Page 17
© 2014-2019 S.A.S. of Luxemburg, LLC.
PREVENTATIVE MAINTENANCE (PAGE 17)
ROTATOR RLP-902 SPECIFIC GREASING
Place grapple on firm level surface, turn off machine & avoid pinch points.
Lubricating the RLP rotator (For models: SAS EXTREME EX-25 v2 & v3 )
Lubricate the RLP rotator after it has been working for several hours because the new grease penetrates
more easily when the old grease is hot. If the working environment contains a high percentage of dirt
and/or humidity, the lubrication period must be shortened.
Recommended grease
This grease can also be used in winter conditions. Avoid mixing different types of grease. Grease should
have excellent water-repulsion durability, antirust capabilities, adhesive abilities and mechanical stability.
Lubrication interval chart
Grease nipple locations
Raceway (2 nipples)
Gear (1 nipple)
Brand
Raceway
Gear
Grapple Pins
Mobil *
(11/4/2016 Per Eric @ Harlon Oil)
Centaur Moly EP2 * Centaur Moly EP2 *
Centaur Moly EP2 *
Mobil
Mobilux EP2
Centaur Moly EP1
Mobilegrease CM-P
Shell
Albida EP2
SRS 2000 Extreme EP2
Comparable
Petro-Canada
Precision EP2
XCG-Flex EP1
Comparable
Mobil
Mobilux EP2
Centaur Moly EP1
Comparable
Exxon
Beacon EP2
Ronex Extra Duty Moly EP2 Comparable
Chevron Texaco
Multifak EP2
Open Gear 100 NC
Comparable
RLP-902
Raceway
Gear
Grapple Pins
Quantity of nipples 2 nipples
1 nipples
5 nipples
Every 10 hours
operating
0 none
2 shots of grease
2 shots grease
Every 40 hours
operating
4 shots of grease 6 shots of grease
2 shots grease