SECTION THREE: USING YOUR CLEANING SYSTEM
P a g e
| 26
108268/49-053 Rev M LEGEND BRANDS MODEL APEX 570
CHEMICAL PUMPING SYSTEM
The chemicals are drawn from the chemical container through a strainer into the flow meter mounted on the control
panel. The flow meter indicates the rate of chemical flow.
The chemicals then flow through the stainless steel chemical pump, the chemical is then injected into a three way
selector valve located on the front panel. This valve may be used to turn the chemical flow ON, OFF, or to PRIME the
chemical pump.
The chemicals then flow through the chemical metering valve to the solution outlet. This valve controls the rate of flow
of chemical into the cleaning solution, which is indicated on the flow meter.
Summary of Contents for APEX 570