SECTION THREE: USING YOUR CLEANING SYSTEM
P a g e
| 36
108268/49-053 Rev M LEGEND BRANDS MODEL APEX 570
SHUT DOWN AND DAILY MAINTENANCE
1.
Flush out the chemical system with fresh water to remove any chemical residue.
2.
Remove as much moisture from the vacuum hoses as possible to prevent spillage of wastewater in your vehicle
when returning hoses. Disconnect the vacuum hose from the front of the unit.
3.
Adjust the throttle cable to the idle position.
4.
Switch the temperature control to the lowest setting.
5.
Allow the unit to run for at least 5 minutes with the bypass valve open. This will also help to remove any excess
moisture from the vacuum pump and cool the unit down.
NOTE:
If shutting down for the day: Plug the vacuum inlet on the front of the unit and set the throttle to high. Spray a
quality silicone or Teflon/PTFE based lubricant into the blower lubrication cup for 5 seconds. Let machine run 2 minutes
to disperse lube to blower.
6.
Unplug the vacuum inlet and remove load. Next, return the throttle control cable to idle position, and let idle for
3 to 5 minutes.
7.
Turn the ignition switch to the OFF position.
8.
Turn the water supply faucet off. Loosen the water supply hose at the water supply to bleed off any pressure.
Unhook the water supply hose and return it to the vehicle.
9.
Activate the valves on all cleaning tools. This will relieve any remaining pressure. Disconnect the cleaning tools
and solution hoses and return them to the vehicle.
10.
Drain the waste tank, disposing of wastewater in a suitable and proper location.
11.
Remove the strainer basket from the waste tank. Clean out any debris and re-install. Micro-ban QGC cleaner is
the best product for cleaning and sanitizing the waste tanks as well as other parts of the system
12.
Inspect the vacuum inlet filter inside the waste tank daily. Remove and clean the filter if there is any lint or
debris present.
NOTE:
To remove or install the mesh filter, grip the plastic hexagon section of the filter. Gripping the filter by the screen
will collapse or destroy the filter. Grease the threads on the filter when replacing. Hand tighten, then loosen ¼ turn. This
will make the filter easier to remove later.
13.
At the end of the work day, rinse out the waste tank with fresh water. Microban QGC cleaner as the best
product for cleaning and sanitizing the waste tanks as well as other parts of the system
14.
Clean the vehicle interior, unit, tools, hoses etc., as needed. Inspect ALL equipment and accessories for any
damage, leaks, wear, etc.