RECORD SET
3
English
71
6
Turn the jog dial to set “DURATION” (10
SEC for example), and then turn the
shuttle dial clockwise.
(Default setting: 1 MIN)
The cursor moves to “ALARM TRIGGER”.
Press the [EXIT] button.
The setting procedure is ended and the display returns to
the normal screen.
“PRE” appears in the operation display area. When an
alarm occurs, “ALARM” is displayed.
z
Pre-alarm recording is carried out over the period
before alarm input as set by “DURATION”. In order to
playback pre-alarm recordings, carry out alarm search
(using the [SEARCH] button). (
J
P.27)
As playback begins at the point of alarm occurrence,
use the shuttle dial to move back into the area of pre-
alarm recording.
z
When normal recording and pre-alarm recording are
performed simultaneously, audio will not be recorded
together with pre-alarm video.
Use this setting to indicate how alarms are to be detected.
1
Turn the jog dial to select “ALARM
TRIGGER”, and then turn the shuttle
dial clockwise.
“ALARM” flashes in the alarm trigger field.
2
Turn the jog dial to select an alarm
detection method, and then turn the
shuttle dial clockwise.
[Settings] (
indicates the default setting)
[Setting conditions]
z
When sensor selection has been made (i.e.,
“SENSOR”, “ALARM AND SENSOR”, or “ALARM OR
SENSOR”) it will be necessary to set the motion
sensors.
When pre-alarm recording settings have been
completed
EXIT
01-01-04 00:00:00 REC REPEAT EN A PRE 0000
02
Number of alarm
PRE display
Setting the alarm trigger
Setting
Description
ALARM
Alarm recording is performed when an
external alarm is generated (i.e.,
when a switch is attached to the alarm
input terminal on the rear panel, and
the switch is activated).
SENSOR
Alarm recording is performed when a
motion sensor detects movement.
See the section on setting motion
sensors for more details.
ALARM AND
SENSOR
Alarm recording is performed when
both the external alarm and a motion
sensor are activated simultaneously.
ALARM OR SENSOR
Alarm recording is performed when
either the external alarm or a motion
sensor is activated.
e00_l8hbe_us_7.book Page 71 Friday, April 16, 2004 1:42 PM