14
CAUTION
・ NO CONTACT WITH ROTAING PARTS DURING TEST RUN
When switching ON, ensure that the flexible polishing pad is not in contact with a
work piece and any substances. Such contacts could cause injuries.
・ DURING TEST RUN, ANY OTHER PEOPLE SHALL KEEP AWAY
Only limited person, however, who is allowed to access to the test run area by
management, would be possible to access the test run area.
・ BE CAREFUL NOT TO DAMAGE THE AIR HOSE AND THE WATER HOSE
(1) Referring to Figure 5 in page 8, adjust the pressure of compressed air so that it
rotates at the speed specified by the manufacturer of flexible polishing pad.
(2) Close the airflow control valve fully and open again slightly.
(3) Turn ON the switch lever
(4) Adjust the airflow control valve slowly until it opens completely little by little
(5) With this condition, make test run for the specified period of test run time described
below in this page.
Continuing the test run and / or polishing operation with the damaged flexible polishing
pad will be very hazardous. Before starting test run, ensure that any other person is
not around and the polisher is in proper condition while test run.
TEST RUN TIME :
Whenever flexible polishing pad is replaced more than 3 minutes
Whenever daily polishing operation is started more than 1 minute