4
Instruction Manual for Sanuvair
®
S300
1-888-726-8869
www.sanuvox.com
SETUP & INSTALLATION
What you will need
Utility knife, scissors, wire cutters, air inlet grid (optional), air outlet grid (optional), suitable wall plugs and screws (as needed),
screwdriver, pliers, masking tape, felt pen, two 8" collars (optional) and suspensions rods (optional).
CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack,
install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit
or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.
What’s included
The SANUVAIR
®
S300, a MERV9 prefilter, a HEPA filter, a UV lamp, the access door for the lamp and ballast (white metal plate)
and a basic installation kit.
The installation kit includes: a pair of cotton gloves, a paper template for duct installation, 17" mounting angles (2), a 3-prong
power cord (6’), self-adhesive foam tape for sealing openings (8’) and self tapping 8/32 x 1/2 screws for the front plate (6).
Special considerations for integrated system installation
•
Verify clearance on the ductwork to mount the unity using the Forced Air / Heating Cooling system;
•
Respect minimum clearance requirement for maintenance and service;
•
Electrical power requirements;
•
Interaction between the HEPA / UV air purifier unit and other mechanical devices.
Step by Step Setup | UV Lamp & Filters
1.
Open the filters and motor access door
of your S300 unit: this is the
large square door closed by the big black clamp.
2.
Check the filters (2):
If they are covered with plastic wrap, be sure to
unpack them before proceeding.
NOTE:
Make sure to install filter(s) according to air flow direction for
maximum performance.
3. Under the HEPA filter is the cardboard sleeve containing the UV lamp.
Carefully slide the UV lamp out from the cardboard sleeve.
Be sure
to wear the cotton gloves (included) ensuring the lamp is free from
fingerprints.
NOTE: Fingerprints on the lamp will negatively impact the UV output of
the lamp.
STEP 1
STEP 2
STEP 3