MAINTENANCE
How to Replace Lamp
Replace UV lamp every 3 years (residential uses), or every 2 years (commercial uses).
Replacing lamp on the Sanuvair
®
S300 is quick and easy. Simply turn off the power source, unscrew and remove the lamp and
ballast access door (plate), remove and dispose of old lamp, replace with new Sanuvox branded UV lamp, screw back the lamp
and ballast access door (plate) and turn power source back on. See below for detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamp, do not touch lamp glass without gloves.
Step by Step Lamp Replacement
STEP 1
1. Unscrew and remove the lamp and ballast access door to access the
old lamp.
CAUTION:
Before installing or performing maintenance on the unit or
system, TURN OFF AND DISCONNECT the unit or system from all
power sources.
2. Prepare the new lamp.
Remove the contents from packaging. Only
after you have visually inspected the UV lamp should you break the
security seal on the underside of the cardboard sleeve. Be sure to
wear the cotton gloves (included) guaranteeing a clean lamp free
from fingerprints. Fingerprints on the lamp will negatively impact the UV
output of the lamp.
NOTE: Fingerprints on the lamp will negatively impact the UV output of
the lamp.
3. While holding the new UV lamp by its porcelain end-cap, slide it into the
rectangular opening in the front of the unit (above the filters and motor
access door).
STEP 2
STEP 3
STEP 4
4. Carefully push the white connector onto the four pins. The plug is
designed so it can only be installed one way. You may have to rotate the
socket 90° to line up the pins with the holes. The connector will fit into
position.
NOTE:
Too much force applied from the opposite end-cap may break
the lamp.