Instruction Manual for Sanuvair

®

 S300

1-888-726-8869

www.sanuvox.com

WARRANTY

You should first read all instructions before attempting to use this product.

For this warranty to be valid, keep a copy of the proof of purchase.

UV lamp

2 years

Ballast

3 years

Electric Motor

3 years

A.  This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to 

damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered 

manufacturing defects under this warranty.

 

SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

 

Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so 

the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from 

jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B.  At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

C.  This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D.  This warranty does not cover the filters, prefilters or other accessories (if included), except for material or workmanship defects.

Call us toll-free at 1-888-726-8869 or email: 

[email protected]

Please be sure to specify product name.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT 

TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING 

CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

CUSTOMER SERVICE

TO ORDER REPLACEMENT PARTS

PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE

Toll-Free Phone #: 1-888-726-8869

Email: [email protected]

Website: www.sanuvox.com

Please be sure to specify product name.
Replacement parts for this product

BST120/277GL

Ballast with multi-voltage input of 120-277 VAC, 50/60 Hz

LMPHGJ105

T6 High Intensity (UVC) 10.5" ‘J’ shaped UV lamp

MSCFTR10

Prefilter

or the carbon prefilter #

MSCFTR10A

MSCFTR11

HEPA filter

MSCMTR11

Motor, 120V

MSCMTR7

Motor, 230V 

Must be ordered with capacitor #

MSCCAP3

 WARNING

: Use only specified SANUVOX branded replacement UV lamps with your unit or system. 

Use of any other 

lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

Summary of Contents for S300

Page 1: ...bels attached to the UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safet...

Page 2: ...nstallations 6 Step by Step Installation Stand Alone 7 Step by Step Installation Duct Mounted Bypass 8 Step by Step Installation Added Ducts 9 OPERATION 10 How to Operate your Product 10 How to Select Speed 10 How to Read the LED Status Display 10 MAINTENANCE 11 How to Replace Lamp 11 Step by Step Lamp Replacement 11 How to Replace Filters 12 Step by Step Filter Replacement 12 How to Clean your Pr...

Page 3: ...net enclosure The ventilator pulls air through the prefilter and pushes the same air through the HEPA filter which helps reduce 99 97 of particles that are 0 3 microns or larger in size A Lamp Ballast Access Door Plate must be installed once lamp setup are done B LED Status Display C Filters and Motor Access Door D Door Latch E Prefilter F Motor G Door Interlock Switch H Speed Selection Switch I H...

Page 4: ...7 mounting angles 2 a 3 prong power cord 6 self adhesive foam tape for sealing openings 8 and self tapping 8 32 x 1 2 screws for the front plate 6 Special considerations for integrated system installation Verify clearance on the ductwork to mount the unity using the Forced Air Heating Cooling system Respect minimum clearance requirement for maintenance and service Electrical power requirements Int...

Page 5: ...he holes The connector will fit into position NOTE Too much force applied from the opposite end cap may break the lamp 6 Then slide the porcelain tip through the retention clamp NOTE Make sure the lamp is horizontal in this section and not touching the metal walls STEP 7 STEP 8 7 Take the access door for the lamp and ballast from the supplied accessories and position it over the rectangular openin...

Page 6: ...he air inlets and outlets duct mounted bypass OR with added ducts using 8 collars In a commercial setting the S300 unit can be positioned horizontally or vertically on a wall or on a ceiling with angles and suspension rods In a residential environment a ceiling installation with suspension rods is NOT recommended Stand Alone attic Stand Alone basement Duct Mounted Bypass Added Ducts ...

Page 7: ... of the unit top by using the screws already in place Then secure the second mounting angle along the rear edge at the bottom of the unit STEP 1 STEP 2 3 Secure the unit to the wall vertically or horizontally or to the ceiling using suitable wall plugs and screws not included Make sure you have a power outlet nearby to plug the unit into CAUTION Your S300 unit is bulky Make sure that there are alw...

Page 8: ...et and outlet vents that you have made at the rear of the unit 4 Use the self adhesive foam tape and stick it around the outline of the two back openings to ensure their tightness when the unit is attached to the pipe You will probably need to cut the tape into pieces to form the two tape rectangles 7 Install the unit vertically on the duct aligning the openings Secure the unit in place with the s...

Page 9: ...it 5 Install your 8 rigid in aluminum or galvanized or aluminized flexible pipes Your new SANUVAIR S300 is now ready to operate STEP 3 STEP 4 STEP 5 Step by Step Installation Added Ducts 1 Using wire cutters cut the small metal pieces supporting the pre cut 8 round opening at the top of the unit and do the same with the one undererneath You will need to use a blade to cut the paper on top as well ...

Page 10: ...cabinet hinges by holding the top part of the door with one hand and gently tapping on the bottom edge of the door with your hand to release the door from its hinges LED Status Display Door Interlock Switch Inside the unit Speed Selection Switch Ventilation speed maximum 300 CFM Ventilation speed normal 220 CFM How to Select Speed The Sanuvair S300 features two speeds of operation The speed select...

Page 11: ... the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources 2 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints Fingerprints on the lamp will negativ...

Page 12: ...ter Replacement 1 Open the filters and motor access door at the front of the unit Opening the latch on the right side of the unit will permit the door to swing open If necessary the door can be removed from the cabinet hinges by holding the top part of the door with one hand and gently tapping on the bottom edge of the door with your hand to release the door from its hinges 2 After opening the uni...

Page 13: ...c storage ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE The product is rated at 120 240VAC 50 60Hz and 48W See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS...

Page 14: ... found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters prefilters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please ...

Reviews: