Instruction Manual for ASEPT.1X Max
1-888-726-8869
www.sanuvox.com
2. Open the lock with a screwdriver and open the cover.
NOTE: If installed on the wall, lock the cover open with the support
provided inside.
STEP 2
3. Holding the end of the lamp, pull carefully to disconnect the lamp from
its connector.
STEP 3
4. Remove the lamps (2) from the unit.
STEP 4
How to Replace Ballast
Replacing ballast on the ASEPT.1X Max is quick and easy. Simply reach the unit with the proper equipement, such as a
stepladder, turn off the power source, open unit cover, remove and dispose of old ballast, replace with new, close unit cover and
turn power source back on. See below for detailed step by step instructions.
Step by Step Ballast Replacement
1. Turn OFF the ASEPT.1X Max by pushing the power button on the unit.
STEP 1
5. Disconnect the white connectors between the cassette and the
protective envelope.
STEP 5