This section describes how to set adjustment for the output voltage set up in §3.1 “Setting Voltage”.
Three levels on the plus side and three levels on the minus side (about -3V to +3V) can be selected.
①
Press
to display the LCD screen.
②
Press
to change the home menu to the one shown below.
③
Press
to accept it.
④
In the same way, follow the figure below to make selection at each level, as follows:
“Home menu” “Settings group” “Settings” “Values”
⑤
Use
to switch values, and then press
to select a desired value. When the confirmation screen appears, press
again to accept the value.
⑥
Press
to return to the home menu.
Settings group
Settings
Home menu
STATUS
MEASUREMENT
SETTING
MAINTENANCE
CONTROL
SET I/F
SET SYSTEM
Out Vol Adj.
>> 0
Values
-3
1
2
3
Details on settings and values
Value
Description
-3
Set 3 levels on the minus side (about 3V).
-2
Set 2 levels on the minus side (about 2V).
-1
Set 1 level lower on the minus side (about 1V).
0
Output specified voltage as it is.
+1
Set 1 level on the plus side (about 1V).
+2
Set 2 levels on the plus side (about 2V).
+3
Set 3 levels on the plus side (about 3V).
Adjustment can be made by specifying the number of levels, with each level being about 1V.
The adjustment values indicated above are those when the setting in §3.4 “Setting Voltage for
Measurement Display” is “
200V/200V
” or “
100V/200V
” (output voltage 200V type).
If the setting is “
200V/100V
” or “
100V/100V
” (output voltage 100V type), the value becomes half.
The selected value is used for adjustment of the output voltage set in §3.1 “Setting Voltage”.
According to the state of the connected load devices and installation environment, set up the
adjustment.
[SELECT] = OK
[BACK] = Cancel
Default
STATUS
Example: Set adjustment to “
+1
”
Confirm
Accept
S E T T I N G
SET IN/OUT
Out Vol Adj.
+1
-2
-1
SET OPERATION
SET BATTERY
RING Output
SETTING
SET FUNCTION
SET FUNCTION
RUN TIM @PF
SET FUNCTION
Out Vol Adj.
+2
+3
Out Vol Adj
>> +1
SET DEFAULT
*1. Pressing
repeatedly cycles through the
displayed items. If you miss a desired item,
just keep on pressing until you see it again.
*2. To return to the previous level, press
.
*3. When you switch to the values screen, the
value shown is the current value, which is
indicated by “
> >
” .
*4. When a value has been changed and accepted,
it is indicated by “
>>
” (current value).
Tip
*1
*2
*3
*4