This section describes how to set adjustment for the output voltage set up in §3.1 “Setting Voltage”. 
Three levels on the plus side and three levels on the minus side (about -3V to +3V) can be selected.   

 

 Press 

  to display the LCD screen. 

 Press 

  to change the home menu to the one shown below. 

 Press 

  to accept it. 

  In the same way, follow the figure below to make selection at each level, as follows: 

“Home menu”    “Settings group”    “Settings”    “Values” 

 Use 

  to switch values, and then press 

  to select a desired value. When the confirmation screen appears, press 

  again to accept the value. 

 

 
 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Press 

  to return to the home menu. 

Settings group 

Settings

Home menu 

STATUS 

MEASUREMENT 

SETTING 

MAINTENANCE 

CONTROL 

SET I/F 

SET SYSTEM 

Out Vol Adj. 

>> 0

 

Values

-3

 

2

3

Details on settings and values 

Value 

Description 

-3 

Set 3 levels on the minus side (about 3V).   

-2 

Set 2 levels on the minus side (about 2V).   

-1 

Set 1 level lower on the minus side (about 1V).   

Output specified voltage as it is.   

+1 

Set 1 level on the plus side (about 1V).   

+2 

Set 2 levels on the plus side (about 2V).   

+3 

Set 3 levels on the plus side (about 3V).   

Adjustment can be made by specifying the number of levels, with each level being about 1V.   

The adjustment values indicated above are those when the setting in §3.4 “Setting Voltage for 

Measurement Display” is “

200V/200V

” or “

100V/200V

” (output voltage 200V type).   

If the setting is “

200V/100V

” or “

100V/100V

” (output voltage 100V type), the value becomes half.

The selected value is used for adjustment of the output voltage set in §3.1 “Setting Voltage”. 

According to the state of the connected load devices and installation environment, set up the 

adjustment. 

[SELECT] = OK 
[BACK] = Cancel 

Default 

STATUS 

Example: Set adjustment to “

+1

”  

Confirm

Accept

S E T T I N G  

SET IN/OUT

 

Out Vol Adj. 
  +1 

-2

 

-1

 

SET OPERATION

SET BATTERY 

RING Output 

SETTING 
SET FUNCTION

 

SET FUNCTION 
RUN TIM @PF 

SET FUNCTION
Out Vol Adj.

+2

 

+3

 

Out Vol Adj 
>> +1 

SET DEFAULT 

*1. Pressing 

  repeatedly cycles through the 

displayed items. If you miss a desired item, 

just keep on pressing until you see it again. 

*2. To return to the previous level, press 

*3. When you switch to the values screen, the 

value shown is the current value, which is 
indicated by “

> >

” .  

*4. When a value has been changed and accepted, 

it is indicated by “

>>

”   (current value).

 

Tip 

*1 

*2 

*3

*4

Summary of Contents for A11J

Page 1: ...LCD Panel Operating Manual M0009235E...

Page 2: ...ing Frequency 10 3 4 Setting Voltage for Measurement Display 11 3 5 Setting PC Interface 12 3 6 Setting Baud Rate 13 3 7 Setting UPS Operation Upon Power Recovery 14 3 8 Setting Buzzer Condition 15 3...

Page 3: ...rning LED WARNING Red Lights Caution warning malfunction or end of battery discharge Output LED OUTPUT Green Lights When supplying power by inverter operation Blinks When supplying power by bypass ope...

Page 4: ...s 8 to 29 Setting setting Change various UPS settings Settings Input output voltage frequency display Interface interface baud rate Operation startup condition buzzer sound off operation overload oper...

Page 5: ...een may be different from the text and position described in the operating manual STATUS Note S E T T IN G S E T OP E R AT I O N Press to return to previous level Press to move to next level S E T T I...

Page 6: ...ous malfunction Output Stop HV Bypass output stopped excessive voltage FIN Temp Error Fin temperature error serious malfunction Over Load Overload DSP Error Controller error serious malfunction Vo V F...

Page 7: ...NT OUTPUT MEASUREMENT BATTERY MEASUREMENT CHARGER MEASUREMENT TEMPERATURE MEASUREMENT Vin V Iout A LF Watt kW Fout Hz ChgRate RunTm Min Ichg A MEASUREMENT T Amb C POWER Failure Times BATTERY Life Year...

Page 8: ...er recovery operation Set UPS operation to perform when utility power recovers after UPS stops due to end of battery discharge in power outage Auto Auto start 3 7 14 Any Condition Always start STOP St...

Page 9: ...5 ChA Total Unit Number of units in ChA system parallel connection Set the number of UPS units connected in the UPS system 1 3 1 unit 2 3 19 26 2 2 units 3 3 units 4 4 units 5 5 units 6 6 units 7 7 un...

Page 10: ...e Settings group Settings Home menu STATUS MEASUREMENT SETTING MAINTENANCE CONTROL SETTING SET IN OUT SET IN OUT Voltage SET I F SET OPERATION SET BATTERY SET FUNCTION SET SYSTEM FREQ Range Frequency...

Page 11: ...he UPS tends to switch to the asynchronous operation To connect to output of the engine power generator select 5 During the asynchronous operation if the UPS switches to the bypass operation this will...

Page 12: ...lues screen the value shown is the current value which is indicated by 4 When a value has been changed and accepted it is indicated by After you restart the UPS the indication becomes current value Ti...

Page 13: ...sp la y 200V 200V S Values 100V 100V Display 200V 100V 1 2 3 Details on settings and values Value Description 200V 200V S If rated input voltage and output voltage are both 200V type This is the defa...

Page 14: ...ATION SET BATTERY SET FUNCTION SET SYSTEM Baud Rate In te rf ac e WS Values Terminal Interface Standalone 1 2 3 Details on settings and values Value Description Standalone Standalone Select this value...

Page 15: ...NTROL SETTING SET I F SET I F Baud Rate SET OPERATION SET BATTERY SET FUNCTION SET SYSTEM Ba ud R at e 9600 Values 2400 Baud Rate 4800 1 2 3 Details on settings and values Value Description 9600 Baud...

Page 16: ...ass power is used BATT 30 More than 30 The UPS restarts automatically when battery charge reaches 30 if the utility power recovers BATT 50 More than 50 The UPS restarts automatically when battery char...

Page 17: ...tery operation battery testing battery voltage error low battery voltage overload bypass operation battery life end warning battery life end serious malfunction minor malfunction end of discharge requ...

Page 18: ...L SET I F SET BATTERY SET FUNCTION SET SYSTEM OFF Operation 1 Sec Values Unique SELECT OK BACK Cancel Example Shut down UPS in 3 Sec 3 seconds Confirm Accept SE TT IN G SET IN OUT SETTING SET OPERATIO...

Page 19: ...eep on pressing until you see it again 2 To return to the previous level press 3 When you switch to the values screen the value shown is the current value which is indicated by 4 When a value has been...

Page 20: ...ription OFF Stop When the button is OFF the UPS stops and power is not supplied BYPASS Bypass power supply When the button is OFF power switches to bypass power supply continues Default SET OPERATION...

Page 21: ...the battery s remaining capacity is less than 5 minutes issue warning 10 Min 10 minutes When the battery s remaining capacity is less than 10 minutes issue warning The time minutes is only an approxim...

Page 22: ...Details on settings and values Value Description 2 Min 2 minutes Run battery test for 2 minutes 5 Min 5 minutes Run battery test for 5 minutes 10 Min 10 minutes Run battery test for 10 minutes 20 Min...

Page 23: ...ery 90 days 30 Days 30 days Run battery test automatically every 30 days None No Do not run battery test automatically This function is available only when Auto is set in 3 3 Setting Frequency If 50Hz...

Page 24: ...minute Provide backup for 1 minute and then stop output supply 3 Min 3 minutes Provide backup for 3 minutes and then stop output supply 5 Min 5 minutes Provide backup for 5 minutes and then stop outp...

Page 25: ...T I F SET SYSTEM RING Output None Values 1 2 3 Details on settings and values Value Description None Do not output RING signal Output Output RING signal when the UPS starts If Output is selected it is...

Page 26: ...l on the plus side about 1V 2 Set 2 levels on the plus side about 2V 3 Set 3 levels on the plus side about 3V Adjustment can be made by specifying the number of levels with each level being about 1V T...

Page 27: ...the previous level press 3 When you switch to the values screen the value shown is the current value which is indicated by 4 When a value has been changed and accepted it is indicated by current value...

Page 28: ...Unit 1 Values 2 1 2 3 Details on settings and values Value Description 1 One UPS unit is used The default is different depending on the UPS model 2 2 UPS units are connected 3 3 UPS units are connect...

Page 29: ...operation system where there is one UPS unit Parallel operation system where total capacity of UPS units in parallel connection is used as connectable load capacity in operation If N 1 is selected wh...

Page 30: ...se this value SELECT OK BACK Cancel Default STATUS Example Set input phase to 3Ph 4W 3 phases 4 wires Confirm Accept SE TT IN G SET IN OUT INPUT Phases 3Ph 4W SET OPERATION SET BATTERY SET FUNCTION SE...

Page 31: ...TUS Example Resetting the settings Confirm SE TT IN G SET IN OUT SET OPERATION SET BATTERY SET FUNCTION SETTING SET DEFAULT SET SYSTEM SETTING SET DEFAULT Reset For the following settings resetting th...

Page 32: ...then start it is different For details refer to UPS Operation in the A11J Instruction Manual Before you stop the UPS be sure to stop the load devices first What is restarting Stop load devices Stop U...

Page 33: ...K Normal termination STATUS Test status Test Condition Test result Possible Test can start 4 2 34 Impossible Test cannot start Testing Test in progress Last Test Time Date of last test YY MM DD HH MM...

Page 34: ...scription Test Condition Test condition Possible Test can start Impossible Test cannot start Testing Test in progress Last Test Time Date and time of last battery test YY MM DD HH MM YY MM DD HH MM If...

Page 35: ...MAIN MCCB is set to OFF UPS s OFF operation is performed Battery test is canceled by power management software Note on battery test Cases where battery test is not possible While inverter stops During...

Page 36: ...Condition Last Test Time YY MM DD HH MM Last Result BA TT ER Y TE ST St ar t Battery test s displayed content Item Content Display Description Display Description Test Condition Test condition Possib...

Page 37: ...until you see it again 2 To return to the previous level press 3 If Wait appears use to go back and try again If the operation still fails contact your supplier or SANYO DENKI SETTING BYPASS CONTROL...

Page 38: ...peration with instant interruption You can also switch the UPS operation to the bypass operation using Forced Bypass inside the front panel of the UPS Note that during the bypass operation if you set...

Page 39: ...rvice technician to perform maintenance of the UPS Even though details are described in 6 Menu List do not use the menu to perform any operation This term is used to indicate service technicians from...

Page 40: ...or malfunction LF CHG Load factor Charging rate Total Unit Err Total number of units error serious malfunction LF Tim m Load factor Charging duration minutes LCD Error LCD panel error Byp Fuse Error B...

Page 41: ...iming Set when to issue battery voltage low warning Voltage When battery voltage threshold is detected 2 Min When 2 minutes left in battery capacity 3 Min When 3 minutes left in battery capacity 5 Min...

Page 42: ...erent depending on UPS model 10Min 10 minutes 15Min 15 minutes 25Min 25 minutes 30Min 30 minutes 35Min 35 minutes 45Min 45 minutes 60Min 60 minutes 120Min 120 minutes 180Min 180 minutes 360Min 360 min...

Page 43: ...number of load devices Bypass SW ON Bypass switch ON The forced bypass switch Forced Bypass is set to Bypass Req To Restart Restart is necessary Values for settings are changed but they require resta...

Page 44: ...s However the operating time of which the battery charging rate will be correctly indicated differs depending on the specifications of the UPS configuration of the battery 4 The value indicated by Chg...

Reviews: