Installation
Leg Adjustment
Position the dispensing head and condensing
unit in the appropriate locations. Level both
units by turning the adjustment on each leg
clockwise or counterclockwise (Fig. 1
).
The dis-
pensing head
MUST
be level to operate prop-
erly and must be operated with the legs in-
stalled.
Electrical
Hook-Up
Procedure
Electrical specifications are located on the data
plate (on rear panel of dispensing head and
front panel of condensing unit). Consult local
authorities for information regarding electrical
codes in the area.
Air Circulation
A minimum clearance of 6" around the dis-
pensing head and 10" around the condensing
unit must be maintained for adequate ventila-
tion.
IMPORTANT
AIR CIRCULATION AROUND CONDENSING
UNIT MUST ENABLE A FRESH SUPPLY OF AM-
BIENT AIR, NOT A
RECIRCULATION
OF THE AIR
BEING EXHAUSTED FROM THE UNIT.
Fig. 1
Leg Adjustment
Fig. 2
Drip Tray Bracket Installation
WARNING
IMPORTANT
AIR CIRCULATION AROUND CONDENSER
UNIT MUST ENABLE A FRESH SUPPLY OF
AMBIENT AIR., NOT A RECIRCULATION OF
THE AIR BEING EXHAUSTED FROM THE
2
Drip Tray Bracket Installation
1. Install the legs onto the bottom of the machine.
2. Leave a 1/4” gap in the front legs.
3. Slide right and left drip tray support brackets onto leg
studs with flanges toward center of machine.
4. Tighten legs around supports and level the machine.
5. Place drip tray onto supports and place insert into
drip tray.