Fig. 12
Front Plate Assembly
4. Secure the front plate assembly with the four
plastic knobs. Simultaneously, turn the knobs in
a clockwise direction. Tighten the knobs evenly.
DO
NOT tighten one knob all the way down and
then the other. This may result in front p
l
ate
breakage. Only moderate force is required. Do
not
over tighten.
5. Install the drip tray and drip tray insert .
6. Proceed directly to the
"Sanitizing"
section of
this manual.
Sanitizing
PRIOR TO OPERATION, THE MACHINE MUST BE SANI-
TIZED. THE UNIT MUST HAVE ALREADY BEEN CLEANED
AND LUBRICATED. (NOTE: SANITIZE IMMEDIATELY BE-
FORE USAGE, NOT SEVERAL HOURS BEFORE OR THE
PREVIOUS EVENING). CLEAN AND SANITIZE DAILY.
ALWAYS WEAR PROTECTIVE GLOVES AND
GLASSES WITH SIDE SHIELDS WHEN WORK-
ING WITH CLEANERS, DETERGENTS, AND
SANITIZERS.
ALWAYS READ AND UNDER-
STAND THE MATERIAL SAFETY DATA SHEETS.
1. Before starting the sanitizing procedure, wash
hands with a suitable antibacterial soap.
2. Prepare approximately two (2) gallons of a
warm sanitizing solution equivalent to 200 parts
per million (P.P.M.) chlorine residual or as re-
quired by your local health agency.
3. Fill the freezing cylinder and mix pan with sani-
tizing solution.
4. Set the dasher switch to the "ON" position and
allow the dasher to agitate for approximately
two minutes.
DO NOT
set the freeze switch to
"ON".
5. Open the spigot plunger and dispense all sani-
tizing solution from the machine.
WARNING
WARNING
DO NOT INSERT ANY OBJECTS OR OTHER
TOOLS INTO THE MIX INLET HOLE OR THE
FRONT PLATE DISPENSING HOLE WHILE THE
UNIT IS RUNNING. DAMAGE TO THE MACHINE
OR PERSONAL INJURY MAY RESULT.
6. Set the dasher switch to the "OFF" position.
Proceed directly to the
"Operation"
section of
this manual.
DO NOT RINSE OUT THE MACHINE
9
Assemble gasket on spigot side.
** Warning: Machine damage possible
if nut is installed incorrectly! **
Lubricate flat side of nut with Sani-Gel.
Install flat side of nut toward spigot.