95
0: Invalid
1: Step 1 Output [mSO01]
2: Step 2 Output [mSO01]
3: Step 3 Output [mSO01]
4: Step 4 Output [mSO01]
5: Step 5 Output [mSO01]
6: Step 6 Output [mSO01]
7: Step 7 Output [mSO01]
8: Step 8 Output [mSO01]
9: Step 9 Output [mSO01]
10: Step 10 Output [mSO01]
0(1000):Multi-step speed command 1
( 0-1 step ) [mSS1]
1(1001):Multi-step speed command 2
( 0- 3 steps ) [mSS2]
2(1002):Multi-step speed command 3
( 0-7 steps ) [mSS4]
3(1003):Multi-step speed command 4
( 0-15 steps ) [mSS8]
×
○
○
○ ○
×
○
○
○ ○
×
○
○
○ ○
10
Application function 3 parameters
Control Method
Setting Range
V/f
Wit-
hout
PG
PG
V/f
PG
Para-
meter
Parameter
Functions
Fact-
ory
Defa-
ult
Torque
control
×
○ ○
○
○
Customizable Logic:
Step 8 Logic circuit
Customizable Logic:
Step 8 Type of timer
Customizable Logic:
Step 8 time setting
Customizable Logic:
Step 9 input 1
Customizable Logic:
Step 9 input 2
Customizable Logic:
Step 9 Logic circuit
Customizable Logic:
Step 9 Type of timer
Customizable Logic:
Step 9 time setting
Customizable Logic:
Step 10 input 1
Customizable Logic:
Step 10 input 2
Customizable Logic:
Step 10 Logic circuit
Customizable Logic:
Step 10 Type of timer
Customizable Logic:
Step 10 time setting
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Same with 10
.
03
Same with 10
.
04
Same with 10
.
05
Same with 10
.
01
Same with 10
.
02
Same with 10
.
03
Same with 10
.
04
Same with 10
.
05
Same with 10
.
01
Same with 10
.
02
Same with 10
.
03
Same with 10
.
04
Same with 10
.
05
0
0
0.00
0
0
0
0
0.00
0
0
0
0
0.00
10
.
38
10
.
39
10
.
40
10
.
41
10
.
42
10
.
43
10
.
44
10
.
45
10
.
46
10
.
47
10
.
48
10
.
49
10
.
50
Same with 10
.
01
Same with 10
.
02
Same with 10
.
01
Same with 10
.
02
Customizable Logic
output signal 1 output
selection
Customizable Logic
output signal 2
output selection
Customizable Logic
output signal 3
output selection
Customizable Logic
output signal 4
output selection
Customizable Logic
output signal 5
output selection
Customizable Logic
Output Signal 1
function selection
Customizable Logic
Output Signal 2
function selection
Customizable Logic
Output Signal 3
function selection
Customizable Logic
Output Signal 4
function selection
Customizable Logic
Output Signal 5
function selection
10
.
71
10
.
72
10
.
73
10
.
74
10
.
75
100
100
×
○
○
○ ○
100
4(1004):Select ACC/DEC time (2steps)
[mRT1]
5(1005):Select ACC/DEC time (4steps)[mRT2]
6(1006):Enable 3-wire operation [mHLD]
7(1007):Coast to a stop [mBX]
×
○
○
○ ○
×
○
○
○ ○
×
○
○
○ ○
×
○
○
○ ○
100
100
10
.
82
10
.
81
10
.
83
10
.
84
10
.
85
0