MP9311 User’s Guide
48
Using the Wt Command
The
Wt
command can also be used to write the Kill and Access passwords and the TID
and User Memory banks. The
Wt
command requires the use of the EPC ID of the tag.
The format of the
Wt
command is as follows:
}Wt, b:<data> ,d:<tag id> a:<block address >[,l:<length>]
[,s:<offset>][, f:<flags>]!
where:
a:<block address>
is the block address (0 by default). For EPC1, Gen2
0=Reserved,1=EPC, 2=TID, 3=USER memory bank
b:<blk data>
is the block data to write. Must be 16-word multiple.
d:<tag ID>
is the tag identification.
l:<# blks>
is the length in 16-bit words. Defaults to length of data if missing.
s:<offset>
is the offset to start write (EPC1, Gen2 only). Defaults to 0 if missing.
f:<xxx>
is protocol specific flag data. Set f=1 for read back/verify. EPC1, Gen2 tags
provide SUCCESS/FAIL feedback. Defaults to 0.
To write the Kill password to a tag with EPC ID= 332233445566778899aabbcc, enter:
}wt,d:332233445566778899aabbcc,a:0,b:33223344!
Summary of Contents for MP9311 Series
Page 1: ...User s Guide MP9311 Low Power UHF Reader Module THE POWER TO CHOOSE...
Page 6: ...MP9311 User s Guide iv...
Page 12: ...MP9311 User s Guide 6...
Page 34: ...MP9311 User s Guide 26...
Page 58: ...MP9311 User s Guide 50...
Page 59: ......