MP9311 User’s Guide
16
MP9311 Power Up and Initialization
When the power supply is connected, the MP9311 starts an internal initialization
sequence.
After the initialization sequence, the reader activates the RF field and, depending
on the configuration, begins transmitting read detect (Rd) commands at the
specified frequency.
Setting the RF Mode
The MP9311 is factory configured for continuous RF scanning or “auto-read” mode. This
mode is equivalent to mode selected by the
Auto Read
function key on the RF Command
Suite
Command
interface window.
If desired, you can reconfigure the reader for Polled RF mode (reader activates the
transmit carrier and waits for host to send a read command). Select the
Polled Read
function key to activate Polled RF mode.
To halt the Auto Read or Polled Read mode, press the
RF Off
function key.
Selecting Tag Protocols
The MP9311 is factory configured with only those protocols selected by the user. Once
protocols are activated, the
Command
tab function keys can be used to select the protocol.
These function keys are programmed with specific command sequences required by the
reader to select a particular protocol. To select a specific protocol, perform the following:
1. Select the
Command
interface window.
2. Select
Function Set
2 or 3 and locate the required protocol.
3. Press the function key to select the protocol.
4. To view the command sequence performed by this function, hold the mouse pointer
over the key or right click while holding the mouse pointer over the key and select
Edit Macro
.
5. Do not change the command sequnce unless you are experienced using SAMSys
CHUMP commands to configure readers.
Summary of Contents for MP9311 Series
Page 1: ...User s Guide MP9311 Low Power UHF Reader Module THE POWER TO CHOOSE...
Page 6: ...MP9311 User s Guide iv...
Page 12: ...MP9311 User s Guide 6...
Page 34: ...MP9311 User s Guide 26...
Page 58: ...MP9311 User s Guide 50...
Page 59: ......