MMC: 833
value is
01800
, meaning a check will be performed every 1.8
seconds. A setting of
00000
means that no periodic checks will
be performed. The maximum setting is
65535
.
ALIVE STS:
ENTRY1 AVAIL ~ ENTRY4 AVAIL:
These entries display the status of the devices at
IP ADDR 1 ~
4
. This status is based on a simple ping test and may not
necessarily imply full connectivity.
SIG TYPE:
This option specifies the TCP/IP communications protocol to
use. The available selections are
UDP
(the default) and
TCP
.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPEAKER
Used to store data and advance to next MMC
ACTION
DISPLAY
1. Press TRANSFER 833.
Display shows the first table number.
TB(000)IP ADDR 1
165.213. 97.185
2. Dial the selected table number using the
KEYPAD (eg. 101)
TB(101)IP ADDR 1
165.213. 97.185
OR
Press UP or DOWN key to select a table and
press RIGHT soft key to move cursor.
3. Press UP or DOWN key to select a table entry
OR
TB(000)IP ADDR 1
165.213. 97.185
Press RIGHT soft key to move cursor.
4. Using the keypad input a 12 digit IP address
TB(000)IP ADDR 1
165.213. 97.185
5. Press UP or DOWN key to select the next
table entry or table option
TB(000)IP ADDR 1
192.168. 1. 10
6. Press TRANSFER to store and exit
OR
Press SPEAKER to store and advance to next
MMC entry.
Home Page