36
Field setting mode
English
Fiel
d S
etting Mode
Field Setting Value (FSV) 40**
Code 40** : User’s options for heating devices including internal backup heater and external boiler
࡙
The values in the following table are just examples for your understanding.
Main Menu &
Code
Menu
Function
Sub
Code
MODEL CODE :
AE200(260)RNW***
MODEL CODE :
MIM-E03CN
Setting Standard
Setting Standard
Item
Step Unit
Default Min.
Max.
Default Min.
Max.
Heating
Code 40**
Heating
Heat
Pump
Heating / DHW
priority
-
-
4011 0 (DHW)
0
1
(Heating)
0
(DHW)
0
1
(Heating)
Low Outdoor
Temp. for
Heating Priority
1
ઑA
4012
0
-15
20
0
-15
20
Heating Off Temp . 1
ઑA
4013
35
14
35
35
14
35
Backup
Heater
On/Off
-
-
4021 0 (No)
0
2
0 (No)
0
2
BUH/BSH Priority
1
-
4022 2 (BSH)
0
(Both)
2 (BSH) 0 (Both) 0
2 (BSH)
Cold weather
compensation
-
-
4023 1 (Yes) 0 (No)
1
1 (Yes)
0
(No)
1
Threshold Temp.
1
ઑA
4024
0
-25
35
0
-25
35
Defrost Backup
Temp.
5
ઑA
4025
15
10
55
15
10
55
Backup
Boiler
Back-up Boiler
On/Off
-
-
4031 0 (No)
0
1 (Yes)
0 (No)
0
1 (Yes)
Boiler Priority
-
-
4032 0 (No)
0
1 (Yes)
0 (No)
0
1 (Yes)
Threshold
Condition
1
ઑA
4033
-15
-20
5
-15
-20
5
Mixing
valve
Application
1
-
4041 0 (No)
0
2
0 (No)
0
2
Ɵɇθ˝ʪϩॳƟ࣍²ʪɇϩ̈͝˝࣎
1
ઑA
4042
10
5
15
10
5
15
Ɵɇθ˝ʪϩॳƟ࣍Aͱͱ̷̈͝˝࣎
1
ઑA
4043
10
5
15
10
5
15
Control factor
1
-
4044
2
1
5
2
1
5
Control interval
1
min 4045
2
1
30
2
1
30
Running Time
3
(x10)
min
4046
9
6
24
9
6
24
Inverter
Pump
Application
-
-
4051
1
0
2
1
0
2
Ɵɇθ˝ʪϩॳƟ
1
ઑA
4052
5
2
ߩ
5
2
ߩ
Control factor
1
-
4053
2
1
3
2
1
3
Addition
Function
Zone controll
1
-
4061 0 (No)
0
1 (Yes)
N/A
N/A
N/A