39
English
Fiel
d S
etting Mode
Field Setting Value (FSV) 50**
Code 50** : User’s options for extra functions
࡙
The values in the following table are just examples for your understanding.
Main
Menu &
Code
Menu
Function
Sub
Code
MODEL CODE :
AE200 (260)RNW***
MODEL CODE :
MIM-E03CN
Setting Standard
Setting Standard
Item
Step Unit
Default Min. Max. Default Min. Max.
Others
Code
50**
Outing Mode
Water Out
Temperature
for Cooling
1
ઑA
5011
25
5
25
25
5
25
Room Temperature for
Cooling
1
ઑA
5012
30
ߢߩ
30
30
ߢߩ
30
Water Out
Temperature
for Heating
1
ઑA
5013
15
15
55
15
15
55
Room Temperature for
Heating
1
ઑA
5014
16
16
30
16
16
30
Cooling WL1 Temp.
1
ઑA
5015
25
5
25
25
5
25
Cooling WL2 Temp.
1
ઑA
5016
25
5
25
25
5
25
Heating WL1 Temp.
1
ઑA
5017
15
15
55
15
15
55
Heating WL2 Temp.
1
ઑA
ߦߡߢߩ
15
15
55
15
15
55
DHW tank Temp.
1
ઑA
5019
30
30
70
30
30
70
DHW Saving
DHW Saving Temp
1
ઑA
5021
5
0
40
5
0
40
DHW Saving Mode
1
-
5022
0
0
1
0
0
1
DHW Saving Thermo
on Temp.
1
ઑA
5023
25
0
40
25
0
40
Power Peak Control
Application
-
-
5041 0 (No)
0
1
(Yes)
0 (No)
0
1
(Yes)
Select forced off parts
1
-
5042 0 (All)
0
3
0 (All)
0
3
Using input voltage
-
-
5043 1 (High) 0 (Low) 1
1 (High)
0
(Low)
1
Frequency Ratio Control
-
-
5051 0 (No)
0
1
(Yes)
0 (No)
0
1
(Yes)