PART 11. SVMi-8/SVMi-16E SET UP
11.1 INTRODUCTION
This section provides the additional steps required to set up the SVMi-8/SVMi-16E card
for operation in the iDCS telephone system. Included is information regarding the
Activity LED, HDD LED, Reset Button and Power Requirements.
SVM LED INDICATIONS
There are two LEDs on this card. The HDD LED will flash green whenever the hard disk
drive is being accessed. The Activity (ACT) LED has various indications as defined in
the table below.
SVMi-8 SVMi-16E SVMi-8/SVMi-16E
ACT LED STEADY RED
AP/D+SD Green
PGD Red
SVMi-8 software is not running.
ACT LED OFF
AP/D + SD+PGD
Red
SVMi-8 software is running, no calls
are in progress.
ACT LED STEADY GREEN
No Indication
SVMi-8 software is running, one or
more calls are in progress.
ACT LED FLASHING
GREEN
AP/D+SD Green
HD Flashing
PGD Red
SVMi-8 software is initializing. SVMi-8
is not ready to process calls.
RESET BUTTON
The red button marked RST is the reset button.
Pressing this button during operation will disconnect all callers in SVMi-8/SVMi-16E
and restart the card. It is best to do a proper shut down before pressing the reset
button. Pressing the reset button on a running system can corrupt the SVM database,
use only as a last resort.
POWER REQUIREMENTS
It is important to understand that all the power to run this self contained Voice Mail
system comes from the phone system power supply. Each of the iDCS phone system
power supplies are rated according to how many stations they will support. When SVMi-
8 is installed in the iDCS it counts as 8 stations of the PSU rating regardless of the
number of the VPMs installed. The SVMi-16E counts as 8 stations of the PSU with no
addition VPMS, 10 Stations of the PSU with 1 VPM, and 12 Stations of the PSU with 2
VPMs installed.