iDCS 500 Release 2 / OfficeServ
INSTALLATION
TECHNICAL MANUAL
PART 4 MARCH 2004
4.2
enable a card the system will partially enable certain cards to maximize the capacity of
the power supply. The following table lists the cards that will be partially enabled.
Note: A single card can never be powered by both PSUs at the same time.
Card Type
Partial Power
16 DLI
YES
8 DLI
YES (No KDb Support)
16 SLI
YES
16 MWSLI
YES
8 SLI
YES
8 MWSLI
YES
SLI NO
SVMi-8/SVMi-16E NO
4 BRI
NO
E&M NO
DID NO
GTRK NO
MGI 2
NO
WLI NO
To determine which PSU is supplying each card, or to determine if a card is turned on
or off or how many ports are active on a card MMC 806 can be used to display the
status of each card.
•
P:1
The card is running on PSU 1
•
P:2
The card is running on PSU 2
•
P:N
The card is turned off
•
[ ]
The number of ports available
4.2 CONNECT POWER TO THE SYSTEM
During the initial installation, it is best to verify proper system operation before plugging
in any amphenol-type cables to the MDF. If you have already plugged the cables in,
unplug them.
Home Page
Table of Contents