iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 AUGUST 2003
MMC: 852
Display
Number/
Alm
Code
LCD Display
Alarm
Notification
ON/OFF
Display Definition
48
MNF13
TODC Error
ON/OFF
Time of Day Clock in the DCCP has erred.
49
MNF14
TSW Over Alarm
ON/OFF
TSW capacity has been requested to exceed
the capacity of the available time slots.
Alarm Data = Cabinet (C1,2)
50
MNF15
SLI Fault
ON/OFF
An SLI card has been detected as out of service
via an internal CODEC test.
Alarm Data = Cabinet, Slot, Port (C1,2)
(S1 through 10) (P1 through 8)
51
MNF16
SLI Recovery
ON/OFF
An SLI card detected as out of service has been
detected as in service via internal CODEC test.
Alarm Data = Cabinet, Slot, Port (C1,2)
(S1 through 10) (P1through8)
52
MNF20
NOT USED
OFF
FUTURE USE