KMMC DIGIT TIME
This timer controls the grace period between programming
actions while in a programming session. The timer
automatically returns the system to secure programming
status.
LCR ADVANCE TIME
This timer controls the duration of time before selecting the
next allowable route when a station is allowed to route
advance.
LCR INTER DIGIT
This timer controls the grace period between dialing valid
digits before accessing a trunk.
MS LED ON TIME
This timer controls the duration a Manual Signalling key will
remain on after use.
OFF HOOK RING
This timer controls the duration of time between ring bursts
to a user who has a camped-on call.
OHVA ANSWER TIME
This timer controls the time duration of an OHVA call before
automatic rejection.
PAGE TIME OUT
This timer controls the duration of a page announcement.
PAGE TONE TIME
This timer controls the duration of tone burst heard over the
page prior to the page announcement.
PARK RECALL TIME
This timer controls the duration of time a call is parked
before recalling to the call park originator.
PC-MMC LOCK OUT
This timer monitors the PCMMC activity, drops the link if no
action is created by PCMMC and returns the system back to
secure program status.
PERI-UCD REPORT
This timer is the interval that a periodic UCD report is
provided to an SIO port.
POWER DOWN TIME
This timer monitors the power to the ROM pack to begin
shutdown status.
RECALL DISCONNECT
This is the time an attendant recall will ring before being
disconnected.
RECALL WAIT TIME
This is the time any recall (hold or transfer) continues to
recall at your station before it recalls to the operator.
SMDR START/DIAL