iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 AUGUST 2003
MMC: 852
Display
Number/
Alm
Code
LCD Display
Alarm
Notification
ON/OFF
Display Definition
32
MJE06
NOT USED
OFF
FUTURE USE
33
MJE07
NOT USED
OFF
FUTURE USE
34
MJE08
NOT USED
OFF
FUTURE USE
35
MNF01
Card Out
ON/OFF
A circuit card mounted in a universal slot has
been removed from service or is not recognized
by the Main Control Processor
Alarm Data = Cabinet, Slot (C1,2)
-(S 1 through 9)
36
MNF02
Card In
ON/OFF
A circuit card mounted in a universal slot has
been returned to service.
Alarm Data = Cabinet, Slot (C1,2)
(S 1 through 9)
37
MNF03
IPC Error
ON/OFF
Inter processor communication error has
occurred.
Alarm Data = Cabinet, Slot (C1,2)
(S 1 through 9)
38
MNF04
Trunk Fault
ON/OFF
Out of service trunk detected via loop detect.
Internal CODEC test.
Alarm Data = Cabinet, Slot Port (C1,2)
(S1 through 9), (P1 through8)
39
MNF05
Trunk Recovery
ON/OFF
Out of service trunk detected via loop detect as
out, is now operational.
Alarm Data = Cabinet-Slot Port (C1,2)
(S 1 through 9), (P1 through 8)
40
MNF06
Trunk Disconnect
ON/OFF
Out of service trunk detected via seizure of
trunk. External seizure test.
Alarm Data = Cabinet, Slot Port (C1,2)
(S1 through 9), (P1 through 8)
41
MNF07
Trunk Connect
ON/OFF
Out of service trunk recovered via seizure of
trunk External seizure test.
Alarm Data = Cabinet, Slot Port (C1,2)
(S1 through 9), (P1 through 8)
42
MNF08
SMDR Over
ON/OFF
SMDR buffer above 80% capacity.
43
MNF09
SMDR Under
ON/OFF
SMDR buffer below 80% capacity.
44
MNF10
DSS Alarm
ON/OFF
System capacity of 64 button DSS modules has
been exceeded.
46
MNF11
SIO Out
ON/OFF
IO port has lost DTR
Alarm Data = SIO 1 through 4
47
MNF12
SIO In
ON/OFF
IO port has regained DTR.
Alarm Data = SIO 1 through 4
HOME
PAGE
Table of
Contents
HELP