iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 NOVEMBER 2001
MMC: 511
MSG WAITING LAMP CADENCE
DESCRIPTION:
This MMC defines the cadence (flash rate) of single line telephone message waiting
lamps on phones connected to an 8MWSLI or a 16MWSLI card. There are two main
choices for the MW lamp cadence available, these being continuous and
interrupted as described below.
OPTION KEYS
0 INTERRUPTED
The MW lamp will flash at a rate determined by the timer
settings. The shortest on time is 100ms and the longest on
time is 3000ms. The shortest off time is 100ms and the
longest off time is 3000ms. The timer is adjusted in 100ms
increments.
1 CONTINUOUS
When an 8MWSLI or a 16MWSLI port has a message, the
lamp will be lit steady.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SPEAKER
Used to store data and advance to next MMC
ANS/RLS
Used to select ALL
ACTION
DISPLAY
1. Press TRSF 511
Display shows
MW LAMP CADENCE
CONTINUOUS LED
2. Press 0 or 1 to select CADENCE
OR
MW LAMP CADENCE
INTERRUPT LED
Press UP or DOWN key to make selection
Press RIGHT soft key to advance to step 3
3. Dial new values for interrupt times
(four digits)
MW LAMP CADENCE
2000 2000
Press RIGHT soft key to move cursor back
If valid entry, system returns to step 2
HELP