iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 AUGUST 2003
MMC: 851
ALM
CODE
ALARM
DEFINITION
MJD17 RAM
Error
An error has occurred in the TEPRI or BRI card RAM.
Alarm data = Cabinet, Slot (Cx-Syy)
MJD18 E1
Restart
The E1 card has restarted.
Alarm data = Cabinet, Slot (Cx-Syy)
MJD19 PRI
Restart
The PRI card has restarted.
Alarm data = Cabinet, Slot (Cx-Syy)
MJD20 BRI
Restart
The BRI card has restarted.
Alarm data = Cabinet, Slot (Cx-Syy)
MJD21 PCM
Loss
Loss of PCM coding on a digital facility.
Alarm data = Cabinet, Slot (Cx-Syy)
MJD22 PCM
Recovery
Recovery of PCM coding on a digital facility.
Alarm data = Cabinet, Slot (Cx-Syy)
MNF01 Card
Out
A circuit card mounted in a universal slot has been removed
from service or is not recognized by the system.
Alarm data = Cabinet, Slot (Cx-Syy)
MNF02 Card
In
A circuit card mounted in a universal slot has been removed
from service.
Alarm data = Cabinet, Slot (Cx-Syy)
MNF03 IPC
Error
Inter processor communication error has occurred.
Alarm data = Cabinet, Slot (Cx-Syy)
MNF04 Trunk
Fault
Out of service trunk detected via loop detect. Internal CODEC
test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF05 Trunk
Recovery
Out of service trunk detected via loop detected as out of service
is now operational.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF06 Trunk
Disconnect
Out of service trunk detected via seizure of trunk. External
seizure test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF07 Trunk
Connect
Out of service trunk recovered via seizure of trunk External
seizure test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF08 SIO
TxQ
SIO Tx Queue full error has occurred in the MCP.
Alarm data = SIO number (SIO:x)