71
Press the KEY 2 button to indicate the specification below on the display.
Press time
Display item
Display
Example of indication
1
FAN RPM of air exhaust(Actual
operation RPM)
1120
1200RPM(Indicates only three digits from
thousand's digit)
2
FAN RPM of air supply(Actual
operation RPM)
2090
900RPM(Indicates only three digits from
thourand's digit)
3
INSIDE_TEMP
3025
25˚C(Indicates only three digits from
hundred's digit)
4
OUTSIDE TEMP
4010
10˚C(Indicates only three digits from
hundred's digit)
5
COND_TEMP
5065
65˚C(Indicates only three digits from
hundred's digit)
6
EVA_IN_TEMP
6035
35˚C(Indicates only three digits from
hundred's digit)
7
EVA_OUT_TEMP
7020
20˚C(Indicates only three digits from
hundred's digit)
8
CO
2
sensor value
8135
1350PPM(Indicates only three digits from
thousand's digit)
9
EEV opening
9048
480STEP(Indicates only three digits from
thousand's digit)
t
When you press and holde the KEY2 switch for more than 3 seconds, PBA will be reset (in 40sec.)
DISPLAY OR TACT SWITCH(KEY1, KEY2)
ENGLISH