33
ENGLISH
Nominal dimensions for
cable [mm
2
(inch)]
4/6 (0.006/0.009)
10 (0.01) 16 (0.02)
25 (0.03)
35 (0.05)
50 (0.07) 70 (0.10)
Nominal dimensions for
screw [mm(inch)]
4 (3/8)
8 (3/16)
8 (3/16)
8 (3/16)
8 (3/16)
8 (3/16)
8 (3/16)
8 (3/16)
B
Standard dimension
[mm(inch)]
9.5 (3/8) 15 (9/16) 15 (9/16)
16
(10/16)
12 (1/2)
16.5
(10/16)
16
(10/16)
22 (7/8)
22 (7/8)
24 (1)
Allowance [mm(inch)]
±0.2 (±0.007)
±0.2
(±0.007)
±0.2
(±0.007)
±0.3 (±0.011)
±0.3 (±0.011)
±0.3
(±0.011)
±0.4
(±0.011)
D
Standard dimension
[mm(inch)]
5.6 (1/4)
7.1 (1/4)
9 (3/8)
11.5 (7/16)
13.3 (1/2)
13.5 (1/2)
17.5
(11/16)
Allowance [mm(inch)]
+0.3 (+0.011)
-0.2 (-0.007)
+0.3
(+0.011)
-0.2
(-0.007)
+0.3
(+0.011)
-0.2
(-0.007)
+0.5 (+0.019)
-0.2 (-0.007)
+0.5 (+0.019)
-0.2 (-0.007)
+0.5
(+0.019)
-0.2
(-0.007)
+0.5
(+0.019)
-0.4
(-0.015)
d1
Standard dimension
[mm(inch)]
3.4 (1/8)
4.5 (3/16) 5.8 (1/4)
7.7 (5/16)
9.4 (3/8)
11.4
(7/16)
13.3 (1/2)
Allowance [mm(inch)]
±0.2 (±0.007)
±0.2
(±0.007)
±0.2
(±0.007)
±0.2 (±0.007)
±0.2 (±0.007)
+0.3
(+0.011)
-0.2
(-0.007)
±0.4
(±0.015)
E
Min. [mm(inch)]
6 (1/4)
7.9 (5/16) 9.5 (5/16)
11 (3/8)
12.5 (1/2)
17.5
(11/16) 18.5 (3/4)
F
Min. [mm(inch)]
5 (3/16)
9 (3/8)
9 (3/8)
13 (1/2)
15 (5/8)
13 (1/2)
13 (1/2)
14 (9/16) 20 (3/4)
L
Max. [mm(inch)]
20 (3/4)
28.5
(1-1/8)
30 (1-
3/16)
33 (1-
5/16)
34 (1-3/8)
38 (1-1/2)
43 (1-
11/16)
50 (2)
51 (2)
d2
Standard dimension
[mm(inch)]
4.3 (3/16) 8.4 (1-
3/16)
8.4 (1-
3/16)
8.4 (1-
3/16)
8.4 (1-3/16)
8.4 (1-3/16)
8.4 (1-
3/16)
8.4 (1-
3/16)
Allowance [mm(inch)]
+ 0.2
(+0.007)
0(0)
+0.4
(+0.015)
0(0)
+0.4
(+0.015)
0(0)
+0.4
(+0.015)
0(0)
+0.4 (+0.015)
0(0)
+0.4 (+0.015)
0(0)
+0.4
(+0.015)
0(0)
+0.4
(+0.015)
0(0)
t
Min. [mm(inch)]
0.9 (0.03)
1.15
(0.04)
1.45
(0.05)
1.7 (0.06)
1.8 (0.07)
1.8 (0.07)
2.0
(0.078)
f
f
Connect the rated cables only.
f
f
Connect using a driver which is able to apply the rated torque to the screws.
f
f
If the terminal is loose, fire may occur caused by arc. If the terminal is connected too firmly, the terminal may be
damaged.
Tightening Torque (kgf • cm)
M4
12~18
Communication : F1, F2
3phase AC power : L1(R), L2(S), L3(T), N
M5
20~30
1phase AC power : L, N
•
When connecting cables, you can connect the cables to the electrical part or connect them through the holes
below depending on the spot.
•
Run transmission wiring between the indoor and outdoor units through a conduit to protect against external
forces, and feed the conduit through the wall together with refirgerant piping.
•
Remove all burrs at the edge of the knock-out hole and secure the cable to the outdoor knock-out using lining
and bushing with an electrical insulation such as rubber and so on.
•
Must keep the cable in a protection tube.
•
Keep distances of 50mm or more between power cable and communication cable.
•
When the cables are connected through the hole, remove the Plate bottom.
CAUTION