General

•  All materials supplied in this manual are indispensable for the 

safety of the equipment. 

Users shall establish appropriate safety and health practices 

and determine the applicability of regulatory limitations based 

on the following descriptions before use.

•  This unit contains a high flammable refrigerant, R-290.  

There are fires and explosions when refrigerant leaks.  

Be sure to follow the storage, installation, maintenance 

instructions.  

(Please refer to the reference guide for details.)

•  Always disconnect the air to water heat pump from the power 

supply before servicing it or accessing its internal components.

•  Verify that installation and testing operations are performed 

by qualified personnel.

•  Verify that the air to water heat pump is not installed in an 

easily accessible area (vandalism/ sabotage/ other harmful 

activities).

•  Carefully read the content of this manual before installing the 

air to water heat pump and store the manual in a safe place in 

order to be able to use it as a reference after the installation.

•  For maximum safety, installers shall always carefully read the 

following warnings.

•  Store the user and installation manual in a safe location and 

remember to hand it over to the new owner if the air to water 

heat pump is sold or transferred of ownership.

•  This manual explains how to install an outdoor unit and 

connecting it to the indoor part (hydro unit or control kit).  

Use of other types of devices with the control system may 

damage the device and void the warranty. 

•  The manufacturer shall not be responsible for damages arising 

from noncompliant units or parts.

•  The manufacturer shall not be responsible for damage 

originating from unauthorized changes or the improper 

connection of electric and hydraulic lines. Failure to comply 

with these instructions or to comply with the requirements 

outlined in the "Operating limits" table included in the manual 

shall immediately invalidate the warranty.

•  To prevent serious system damage and user injuries, 

precautions and other notices shall be observed.

•  Failure to comply with these instructions or to comply with 

the requirement on the Operating Range (Heat: -25~35 °C/ 

DHW: -25~43 ℃/ Cool: 10~46 °C) outlined in the Product 

Specification shall immediately invalidate the warranty.

•  Do not use the units if you see some damages on the units and 

recognize something problematic such as loud noise or  

smell of burning.

•  To prevent electric shocks, fires or injuries, always stop the 

unit, ultimately rendering the product powerless. Contact 

Samsung’s technical support if the unit produces smoke, if the 

power cable is hot or damaged or if the unit is very noisy.

•  Always remember to inspect the unit, electric connections, 

refrigerant pipework and protections regularly.  

These operations shall be performed by qualified personnel 

only.

•  The unit contains moving and electrical parts, which should 

always be kept out of the reach of children.

•  Do not attempt to repair, move, alter or reinstall the unit by 

unauthorized personnel. These operations may cause product 

damage, electric shocks, and fires.

•  Do not place containers with liquids or other objects on the 

unit. Never sit or stand on the product.

•  All the materials used for the manufacturing and packaging of 

the air to water heat pump are recyclable.

•  The packing material and exhausted batteries of the remote 

controller(optional) must be disposed of in accordance with 

local regulations.

•  Always make sure that the power supply is compliant with 

local safety standards.

•  For use in Europe: This appliance can be used by children aged 

8 years and above and persons with reduced physical, sensory 

or mental capabilities or lack of experience and knowledge if 

they have been given supervision or instruction concerning the 

use of the appliance in a safe way and understand the hazards 

involved. Children shall not play with the appliance. Cleaning 

and user maintenance shall not be done by children without 

supervision.

•  This appliance is not intended for use by persons (including 

children) with reduced physical, sensory, or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning the appliance use 

by a person responsible for their safety. Children should be 

supervised to ensure they do not play with the appliance.

•  Be sure not to perform power cable modification, extension 

wiring, and multiple wire connection.

 

– It may cause electric shock or fire due to poor connection, 

poor insulation, or current limit exceedance.

•  Do not use means to accelerate the defrosting operation or to 

clean, other than those recommended by Samsung.

•  Do not pierce or burn.
•  Be aware that refrigerants may not contain an odour.
•  Determine the installation location regarding the conditions 

cited in this reference guide and obtain the user’s approval.

•  The outdoor unit must not be placed on its side or upside 

down, as the compressor lubrication oil will run into the 

cooling circuit and seriously damage the unit.

•  Combine R-290 products only or an error signal appears and 

the products will not operate. Check with the compatibility 

table provided by Samsung.

•  Make sure to safely dispose of packing materials. Packing 

materials, such as nails and other metal or wooden pallets may 

cause injuries to humans and animals by unsafe disposal.

Installing the unit

  NOTE

•  When installing the unit, remember to firstly connect 

the water pipework, then the electrical lines. Always 

disassemble the electric lines before the water pipework.

•  Upon receipt, inspect the product to verify that it has not been 

damaged during transport. If the product appears damaged, do not 

install it, as the refrigerant may leak. A leaking product should be 

moved to a safe outdoor place. There should be no ignition source 

within 6 meters. Products should be located where the refrigerant 

can be safely removed or professionally removed and discarded by 

service technicians. Immediately report the damage to the supplier 

of the Samsung products (distributor/retailer/ local Samsung branch 

office)

•  After completing the installation, always carry out a functional 

test (commissioning, including reporting) and provide instructions 

on how to operate the air to water heat pump to the user.

•  Do not use the air to water heat pump in environments with 

hazardous substances or close to equipment that releases 

open flames to avoid the occurrence of fires, explosions or 

injuries.

•  While in installation or relocation of the product, do not mix 

Safety Information

Safety Information

Summary of Contents for AE CXYD Series

Page 1: ...WaterHeatPump Installation manual EHS Mono Outdoor Unit AE CXYD Thank you for purchasing this Samsung product Before operating this unit please read this manual carefully and retain it for future refe...

Page 2: ...14 Connecting the water pipes 14 Water Charging 14 Setting capacity and pre pressure of the expansion vessel 15 Protection of the water circuit freezing 15 Outdoorwater piping insulation 17 Minimum a...

Page 3: ...uman health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users s...

Page 4: ...unit Neversit orstand on the product All the materials used forthe manufacturing and packaging of the airto waterheat pump are recyclable The packing material and exhausted batteries of the remote con...

Page 5: ...ng flammable refrigerants Safety checks are required to minimize the ignition risk for servicing the units containing flammable refrigerants Servicing shall be performed following the controlled proce...

Page 6: ...the recovery units orcylinders If compressors orcompressoroils are to be removed make sure that they have been evacuated to the acceptable level to ensure that flammable refrigerant does not remain in...

Page 7: ...product in the protective packaging and keep covered until final installation Preparation of both horizontal and vertical transport routes and equipment might be required in orderto get the product i...

Page 8: ...d does not generate any unnecessary noise and vibration Position the outdoorunit so that the airflows directly towards the open area Place the outdoorunit where there are no plants and animals because...

Page 9: ...d laterto violate the protection rules Unit mm 1 000 1 000 1 000 500 1 000 500 500 500 300 1 000 500 1 000 1 000 500 When installed on the ground When installed in a place with a flat roof When instal...

Page 10: ...and serviceable undersafe working conditions forpeople orthings Installing the unit at a locationwith strong winds Outdoorunit must be fixed firmly so that it can withstand the wind speed of the stro...

Page 11: ...lean it with waterto remove attached salinity 6 If the protective coating orgalvanised steel of the product is damaged during the installation ormaintenance make sure to repairit 7 Check the condition...

Page 12: ...tions Woodenpallet Forklift 1 050mm NOTE When looking at the product from the front there is a centerof gravity right from the middle of the product Referto the centerof gravity mark attached to the p...

Page 13: ...runs away correctly and safely 150mm WARNING If the drainage is not adequate it can lead to stagnant water and ice build up causing system performance issues and possible damages Drainhole 20 Drainpl...

Page 14: ...ench as specified in the below table If not connections and parts can be damaged and leak The unit is only to be used in a closed watersystem If applications are in open watercircuit it will generate...

Page 15: ...the installation the installation height is considered 0m When Expansion vessel has a capacity 8 liters and1bar pre charged Watervolume of total system forreliable performance is minimum 30 Liter AE0...

Page 16: ...raturevalue When using the EHS forcooling in the summertime an anti freeze valvewith ambient sensoris required to avoid unwanted opening due to lowwatertemperatures To protect the field piping against...

Page 17: ...m Minimum insulation thickness mm 20 19 20 30 32 30 40 40 40 50 50 NOTE This recommendation ensures good operation of the unit however local regulations may differand shall be followed Minimum activew...

Page 18: ...ct the earth wire to the gas pipe water pipe lighting rod ortelephone wire If earthing is not complete electric shock orfire may occur Install the circuit breaker Failing to install a circuit breaking...

Page 19: ...t and route them through the factory mounted cable sleeves into the switch box Powerand communication cable configuration Powersupply cable must be guided through the knock out hole on the bottom righ...

Page 20: ...itchwithinyourarm s reach that disconnects all poles with contact gap of a least 3 mm Route the cable through the frame Connect the wires to the terminal block and fix the cable with the cable tie R S...

Page 21: ...the selected options press and hold the K2 switch for2 seconds to store the value The changed value of the option will be saved when the entire segment display blinks and tracking mode begins CAUTION...

Page 22: ...K 2 BLANK 1 3 times InverterFault Detection Comp 1 K 3 I 1 4 times End Key operation K2 Numberof Press KEY operation 7 segment display 1 time Trial operation in Cooling mode K 4 BLANK BLANK 2 times Di...

Page 23: ...nd on this manual the factory refrigerant charge of the product the additional refrigerant amount charged in the field Unit kg tCO e a b DO NOTCHARGE Refrigerant type GWPvalue R 290 3 GWP Global Warmi...

Page 24: ...e Error Detect when the system is not operated OUTDOOR UNIT E440 Forbid Heat mode Operation when OutdoorTemperature is over43 C OUTDOOR UNIT E441 Forbid Cooling Mode when Outdoor Temperature is Low10...

Page 25: ...T_CT Thermistor CompressorTop T_D Thermistor Discharge pipe T_EI Thermistor EVI In T_EO Thermistor EVI Out T_II Thermistor Heat ExchangerIn T_S Thermistor Suction pipe T_WI Thermistor WaterIn T_WO The...

Page 26: ...HE Part Description CV Check Valve COMP Compressor HX_IC Heat Exchanger Intercooler HX_M Heat Exchanger Main Outdoorunit HX_PHE Heat Exchanger PHE IPMC IPM Cooler OFM OutdoorFan Motor AC Accumulator P...

Page 27: ...with the higher set temperature to Zone 2 d A ir vent included in tank integrated hydro unit In case that the water piping would be located in a higher position than the air vent of the tank integrate...

Page 28: ...essel Decoupler Safety group Safetyvalve Manometer Expansion vessel 3waymixingvalveforfloorheating incaseofcombinationwithradiators Mixing valve temperature sensorb Vibro isolating mounting bases Symb...

Page 29: ......

Page 30: ...This appliance is filledwith R 290 A3...

Reviews: