• Measure the quantity of the refrigerant according to the length
of the liquid side pipe. Due to the small quantity of the R-290
charge, an accurate weighing of the R-290 charged in the
system is mandatory to ensure proper performance.
Important information: regulation
regarding the refrigerant used
Please fill in the following with indelible ink on the refrigerant
charge label supplied with this product and on this manual.
•
①
the factory refrigerant charge of the product.
•
②
the additional refrigerant amount charged in the field.
Unit
kg
tCO₂e
①
, a
②
, b
DO NOT CHARGE
Refrigerant type
GWP value
R-290
3
• GWP: Global Warming Potential
•
Calculating tCO₂e: kg x GWP/1000
R-290
Indoor unit
Outdoor
unit
GWP=3
②
①
NOTE
a
Factory refrigerant charge of the product: see unit name plate.
b
Additional refrigerant amount charged in the field. (Refer
to the above information for the quantity of refrigerant
replenishment.)
CAUTION
• The filled-out label must be adhered in the proximity of the
product charging port.
(ex. onto the inside of the stop valve cover.)
Charging refrigerant
Charging refrigerant