10.2 DETAILS OF PROGRAMMABLE PARAMETERS LISTED IN TABLE 10.1 AND IN FIG 10.1
Table 10.1 provides list of programmable parameters, their programmable ranges, setup options and
default values. Menu Map at Fig 10.1 shows the path to navigate to the setting screen of the desired
parameter. Details of parameters are given in the succeeding Sub-Sections.
10.2.1 Main Menu for Parameter Setup Groups 1-6 > Group 1 “UI Setting” > Sub-Menu for
“UI Setting”
10.2.1.1 “a. LCD Contrast”: Sets LCD screen contrast.
Parameter
Programmable Range
Default
a. LCD Contrast
0% to 100%
50%
NOTE: During operation, the LCD contrast can be adjusted on as required basis and the setting will be saved
automatically when the setting screen is exited. There will no Save / Discard action required for the
new % of contrast setting as done for Save / Discard action for other programmable parameters.
Once the unit is switched OFF, the LCD contrast will be reset to the Default value of 50%.
10.2.1.2 “b. LCD Auto-Off": This parameter can be programmed to control the time the LCD is required to
remain in ON condition. Programmable range is (i) 20 to 180 sec (Default is 60 sec) or (ii) DISABLE i.e. ON all
the time.
• When the LCD Display is in Auto-Off condition, it can be switched back to the Startup Display Screen
by pressing the Down Key
• To switch off the LCD Screen before the expiry of the “LCD Auto-Off” time period, press the Up
Key
Parameter
Programmable Range
Default
b. LCD Auto-Off
20 to 180 sec or DISABLE
60 sec
10.2.1.3 “c. RS232 Speed”: Sets the speed of communication in Bits per Second (bps) over the RS-232 Serial
Communication Port.
Parameter
Programmable Range
Default
c. RS232 Speed
1200/2400/4800/9600/14400/19200/24000/28800
4800
10.2.1.4 “d. USB Virtual COM Speed”: Sets the speed of communication in Bits per Second (bps) over the
USB Virtual Communications Port.
Parameter
Programmable Range
Default
d. USBVCOM Speed
(USBVCOM: USB Virtual Com-
munication)
1200/2400/4800/9600/14400/19200/24000/28800
4800
SECTION 10 |
Programming of Operating Parameters