54 | SAMLEX AMERICA INC.
SECTION 10 |
Programming of Operating Parameters
10.2 SPECIFICATIONS OF PROGRAMMABLE PARAMETERS IN THE MENU MAP AT FIG 10.1
Table 10.1 provides list of programmable parameters shown in the Menu Map at Fig 10.1 along with their
specifications i.e. their programmable ranges, setup options and default values.
TABLE 10.1 PROGRAMMABLE PARAMETERS (REFER TO MENU MAP AT FIG 10.1)
Menu
(1)
Sub Menu
(for Parameter
Groups 1 to 6)
(2)
Sub Menu Item
(Programmable
Parameter)
(3)
Programmable Range
of Sub Menu Item
Programmable Parameter)
(4)
Default Setting
(5)
Main Menu
(For Parameter Setup
Groups 1 to 6)
Group 1 Parameters
1. UI Setting
a. LCD Contrast
0% to 100%
50%
b. LCD Auto-Off
20 to 180 sec or DISABLE
60 sec
c. RS232 Speed
1200/2400/4800/9600/14400/19200/
24000/28800
4800
d. USBVCOM Speed
(USBVCOM: USB Virtual
Communication)
1200/2400/4800/9600/14400/19200/
24000/28800
4800
e. Buzzer Setup
1. Fan Fault
Enabled
Enabled
Disabled
2. OV Alarm
(OV: Over Voltage)
Enabled
Enabled
Disabled
3. UV Alarm
(UV: Under Voltage)
Enabled
Enabled
Disabled
4. Overload
Enabled
Enabled
Disabled
5. Overtemp
(Over Temperature)
Enabled
Enabled
Disabled
6. Short
(Short Circuit)
Enabled
Enabled
Disabled
f. Relay Setup
1. Fan Fault
Enabled
Enabled
Disabled
2. OV Alarm
(OV: Over Voltage)
Enabled
Enabled
Disabled
3. UV Alarm
(UV: Under Voltage)
Enabled
Enabled
Disabled
f. Relay Setup
4. Overload
Enabled
Enabled
Disabled
5. Overtemp
(Over Temperature)
Enabled
Enabled
Disabled
6. Short
(Short Circuit)
Enabled
Enabled
Disabled
Group 2 Parameters
2. Input Setup
a. OVP Setting
(Over Voltage
Protection Setting)
PSR-1200-24: 25.0 to 35.0 VDC
34.0 VDC
PSR-1200-48: 50.0 to 62.0 VDC
60.0 VDC
b. OVP Recovery
(Over Voltage
Protection Recovery)
PSR-1200-24: 24.5 to 34.5 VDC
33.0 VDC
PSR-1200-48: 49.0 to 61.0 VDC
58.0 VDC
c. UVP Setting
(Under Voltage
Protection Setting)
PSR-1200-24: 17.0 to 23.0 VDC
20.0 VDC
PSR-1200-48: 34.0 to 46.0 VDC
40.0 VDC
d. UVP Recovery
(Under Voltage
Protection Recovery)
PSR-1200-24: 17.5 to 23.5 VDC
23.0 VDC
PSR-1200-48: 35.0 to 47.0 VDC
46.0 VDC