48 | SAMLEX AMERICA INC.
TABLE 9.0 LEDS FOR MONITORING OPERATING STATUS (Continued)
Name of
Status LED
Status LED
Color
Operating Status
BYPASS
OFF
CONDITION 1
§
Parameter “Transfer Type” has been set up as
“Synchronized” (Default)
§
Parameter “Inverter Mode” has been set up as
“On – Line”
§
LED marked AC GRID is Green (AC GRID input
is available and IS within the “Synchronizable
Frequency Window”)
§
LED marked INVERTER is Green (Inverter
Section is in ON condition)
CONDITION 2
§
Parameter “Transfer Type” has been set up as
“Unsynchronized”
§
Parameter “Inverter Mode” has been set up as
“On-Line”
§
LED marked AC GRID is Orange (AC GRID
input is available but is NOT within the
“Synchronizable Frequency Window”)
§
LED marked INVERTER is Green (Inverter
Section is in ON condition)
When this LED is off under the above Condition 1,
it indicates the following:
• AC GRID input is NOT being bypassed as “On-
Line” Mode has been selected
• Load is being powered by the Inverter
When this LED is off under the above Condition 2,
it indicates the following:
• AC GRID input is NOT being bypassed as
“On-Line” Mode has been selected
• Load is being powered by the Inverter
ALARM
Orange
Orange LED indicates activation of following protections leading to shut down of the Inverter Section:
• Short Circuit
• Overload
• Over temperature
• Fan failure
• Over Voltage (OV) Protection
• Under Voltage (UV) Protection
9.5 LCD DISPLAY FOR MONITORING OF OPERATING PARAMETERS
LCD Display (6, Fig 6.1) is used for monitoring various operating parameters and also for setup of various
programmable parameters and settings.
Refer to Startup Display and Dashboard portions of the Menu Map at Fig 10.1 (extract of these portions is
given below at Fig 9.1 for ready reference. The “Startup Display” screens appear when the unit is switched
ON (see Section 9.6 for details). The “Dashboard” shows the 5 scrollable screens that provide information
on the operating parameters (see Sections 9.7 for details).
SAM LEX AMER I CA
P S R - 1 2 0 0 - 2 4
F i r mwa r e V e r s i o n
1 . 0 . 2 6 8 5
START UP DISPLAY
(Model No. & Firmware Version)
DASH BOARD
I n v . V 1 2 0 . 0 VAC
G r i d . V 1 1 0 . 0 VAC
I n v . I
1 0 . 0
A
G r i d . I
0 . 0
A
I n v . P 1 2 0 0 . 0 W
G r i d . P
0 . 0 W
I n v . F 6 0 . 0
H z
G r i d . F 6 0 . 0
H z
V i n :
2 4 . 0
VDC
Fig 9.1: Startup Display and Dashboard (extract from Fig 10.1)
SECTION 9 |
Operation